Read Sony SAL70200G2 Service Manual online
5-21
SAL70200G2 (2.8/70-200 G SSM Ⅱ) (70-200mm F2.8 G SSM II)
6) Push the [Enter] key.
7) A focusing error amount (Shooting magnification: 40 times) selection window with a 2.0x teleconverter installed opens.
7) A focusing error amount (Shooting magnification: 40 times) selection window with a 2.0x teleconverter installed opens.
Note:
To adjust the focusing error amount with a 2.0x teleconverter installed, select error mount correcting button on this window.
The error amount (Shooting magnification: 40 times) is input to here.
Fig.
5-10-7
8) Push the [Enter] key.
9) Perform the 5-6. Focusing Error Amount Check again, and check that the error amount is smaller than the reference value.
9) Perform the 5-6. Focusing Error Amount Check again, and check that the error amount is smaller than the reference value.
If the error amount is larger than the reference value, perform [Write
⊿
SB] again, and repeat steps 1) to 9) until the error amount be-
comes less than reference value.