SAL50F14 - Sony Digital Camera Service Manual (repair manual). Page 40

Read Sony SAL50F14 Service Manual online

4-17
SAL50F14 (1.4/50) (50mm F1.4)
4-6.
FOCUS BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK
Note:
If dialog box of error code appears during the checking or adjustment, check the reason of error referring to page 4-20.
4-6-1. Focus Brush Position Check
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Connect the checking lens to the camera.
2)
Start the lens adjustment program “LensAdjustment.exe” referring to “4-1-2. Lens Adjustment Program”.
Fig. 4-6-1
2. Checking Method
1)
Click the 
[Connect]
 button on the lens adjustment program.
Note:
Click the 
[End]
 button to disconnect the USB connection, then lens adjustment program will terminate.
Fig. 4-6-2
2)
Click the 
[Focus]
 button on the lens adjustment program.
3)
Set the focus position to infinity end, then check that the OK (Green) indicator of “Position” lights as shown in Fig. 4-6-3.
Fig. 4-6-3
If the NG (Red) indicator of “Position” lights, perform the “4-6-2. Focus Brush Position Adjustment and Pattern Check”.
Fig. 4-6-4
4)
Click the 
[Exit]
 button.
5)
Click the 
[End]
 button to terminate the lens adjustment program.
6)
Turn the POWER switch of the camera to OFF.
Page of 45
Display