2-9
SAL300F28G2 (2.8/300 G SSM 
Ⅱ) (300mm F2.8 G SSM Ⅱ)
HELP11
Adhesive bond (B-10): J-6082-612-A
Adhesive bond (B-40): J-6082-614-A
Adhesive bond (LOCTITE 460)
Note:
  Use the adhesive bond (LOCTITE 460) or the equivalent.
 
Do not use the instant glue, which becomes white after dried.
1.  Install the aperture connect lever to the iris holding tube block. Apply two drops of adhesive bond (B-40) to the tips of two screws and 
tighten the aperture connect lever with two screws.
2.  Apply the adhesive bond (LOCTITE 460) the indicated portion of iris holding tube block and affix the mount index there.
3.  Install the main spring hook to the iris holding tube block and tighten it with the screw. Then, apply the adhesive bond (B-10) as indi-
cated in the figure.
4.  Install the main spring as shown in the figure and apply the adhesive bond (B-10) to the indicated portion.
Iris Holding Tube Block
Aperture Connect Lever
Aperture Connect
Lever
Main Spring Hook
Main Spring Hook
Main Spring
Main Spring
Main Spring
Mount Index
Apply the adhesive bond
(LOCTITE 460)
Apply the bond
(B-40)
Apply the bond
(B-10)
Apply the bond
(B-10)
HELP12
Cut two polyester tapes in 30mm to make the size of 12 x 30mm and affix them to position shown in the figure below to fix the SW con-
nection FPC block.
CL-033 Board
SW Connection FPC Block
30 mm
12 mm
Polyester Tape
(9X30 mm)
HELP13
Cut six polyester tapes in 30mm length. Affix two sheets of polyester tape cover the area of 12 x 30mm at each location as shown below to 
fix the flexible cards to the board.
Polyester Tape
(9X30 mm)
Polyester Tape
(9X30 mm)
Polyester Tape
(9X30 mm)
Polyester Tape
(9X30 mm)
CL-032 Board
CL-034 Board
30 mm
12
 mm
CL-033 Board
Polyester Tape
(9X30 mm)
Page of 88