Read Sony SAL2470Z2 Service Manual online
2-3
HELP
Note for assembling and grease applying positions are shown.
SAL2470Z2 (Vario-Sonnar 2.8/24-70 ZA SSM II) (Vario-Sonnar T* 24-70mm F2.8 ZA SSM II)
HELP 01
Bond (B-40): J-6082-614-A
1. Attach the Front Lens Barrel ASSY, matching the Gauge point (red) with the index line of focus scale window.
2. Apply the adhesive bond (B-40) to the indicated portions, and tighten the three screws.
2. Apply the adhesive bond (B-40) to the indicated portions, and tighten the three screws.
ft
m
Index line
Focus Scale Window
Front Lens
Barrel ASSY
Barrel ASSY
Index line
Gauge point (red)
Apply adhesive
bond (B-40)
bond (B-40)
HELP 02
1. Leave a wrinkle to the motor flexible.
Motor Flexible
2. Fold it as shown below and fix it with polyimide sheet (6 x 25 mm).
Motor Flexible
Board
Polyimide Sheet
(6 x 25 mm)
(6 x 25 mm)
Motor Flexible
Click on the first or last page to see other SAL2470Z2 service manuals if exist.