SAL18552 - Sony Digital Camera Service Manual (repair manual). Page 7

Read Sony SAL18552 Service Manual online

2-4
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
HELP04
1.  While inserting the aperture interlocking fork in the aperture lever, install the mount block.
 
Mount Block
Aperture Interlocking Fork
Aperture Lever
2.  Select 1 to 2 pieces of back adjustment washers to make a combination of specified thickness.
Note:
  The amount of back adjustment washers differs depending on the adjustment. (Refer to the flange back adjustment.)
3.  Push the back adjustment washers in between the boss and the mount block. (3 locations)
Note:
  When stacking several pieces of back adjustment washers, install the washers so that thin one comes at the outer side.
4.  Tighten the mount block with three screws.
5.  Connect the ZF flexible PWB to the connector of the CL-022 mount block assy.
 
Back Adjustment Washers
Mount  Block
ZF Flexible PWB
Back Adjustment Washers
Back Adjustment 
Washers
Connector of 
CL-022 Mount
Block Assy
Boss
Thin
Thick
HELP05
1.  Set the zoom to somewhere in the range of  28-35  and the focus to the infinity end.
2.  Aligning the character [3.5] on the front decoration plate with the slant portion of bayonet, affix the front decoration plate.
Note:
  Align with the slant portion of bayonet at the tele Stopper side.
 
Front Decoration Plate
Tele Stopper
Slant portion of bayonet
HELP06
1.  Affix the flexible of DC motor (geared) to the fixed holding tube.
2.  Connect the ZF flexible PWB to the connector.
 
ZF Flexible PWB
Connector
Affix the flexible of 
DC Motor (Geared) to 
the Fixed Holding Tube.
Page of 55
Display