SAL18552 - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony SAL18552 Service Manual online

2-6
SAL18552 (DT 3.5-5.6/18-55 SAM Ⅱ) (DT 18-55mm F3.5-5.6 SAM II)
HELP10
1.  Set the zoom to the TELE end and insert the 2nd lens barrel block, aligning the grooves with the projections at three locations.
Note:
  Align the aperture lever with the ZF flexible PWB.
2.  Set the zoom to the WIDE end, and the 2nd lens barrel block is pulled in and fixed.
Note:
  If the zoom is set to the TELE end, the 2nd lens barrel block will be dislocated. Therefore, do not set the zoom to the TELE end.
 
2nd Lens Barrel Block
ZF Flexible PWB
Aperture Lever
Set to the WIDE end.
Set to the TELE end.
Projection
Projection
Projection
The 2nd Lens Barrel Block 
is pulled in and fixed.
Grooves
3.  Install the tele stopper.
Note:
  Install it in the state that the zoom is set to a position other than the TELE end.
4.  Push the zoom to the TELE end and tighten it with one screw.
 
Tele Stopper
Tele Stopper
Push to the TELE end
HELP11
How to remove the zoom interlocking key
1.  Set the zoom to the WIDE end and the focus to the near end. (In the state that the zoom interlocking key and the focus stopper 
locate in the center.)
2.  Remove two screws.
 
Zoom Interlocking Key
Focus Stopper
Set to the WIDE end.
Set the unit to the near end.
3.  Unlock the engagement of the bayonet by moving right and left the zoom barrel assy and shift it in the front lens barrel direction.
4.  Remove the zoom interlocking key.
 
Zoom Interlocking Key
Bayonet