SAL18135 - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony SAL18135 Service Manual online

2-5
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
HELP09
1.  Extend the 1st group movement frame to the position shown in the figure below.
2.  While passing the LF-145 flexible board ZM-AFM8948 (8948) through the hole in the middle barrel assy, install the middle barrel assy 
and the zoom ring assy to the unit.
3.  Set the zoom ring assy to a focal length of 35 mm and extend the 1st group outer barrel assy and the 1st group movement frame to the 
position shown in the figure below to align the zoom ring assy hole with the zoom pin screw hole.
4.  Tighten two zoom pins.
1st Outer Barrel Assy
Center Barrel Assy
Zoom Ring Assy
Zoom ring assy hole and
zoom pin screw hole
PWB (ZM-AFM8948), 
LF-145 FLEX
Hole
Zoom Ring Assy
1 st Moving Frame
Zoom Pin
Zoom Pin
1 st Moving Frame
HELP10
1.  Align the opening of the 1st group outer barrel assy with the opening of the 3rd movement barrel assy, and then install the 1st group 
outer barrel assy to the optical assy while inserting the two projections of the 1st group outer barrel assy into the two grooves of the re-
tainer ring.
2.  Tighten three screws.
1st Outer Barrel Assy
Stationary Barrel
Optical Assy
Projection
Grooves
Grooves
Opening
Opening
Page of 47
Display