1-2
1-5. NOTE ON REPLACEMENT OF SERVICE EXCLUSIVE OPTICS BLOCK
To replace the Service Exclusive Optics Block, connect the lens to the finished Inspection JIG
Ⅱ
, and release the specified plug in the fol-
lowing procedure.
1. Start
up ACSAM-S-Ver.X.XX.exe .
2. Click
[Setup].
Fig.1-5-1
3. Set the following contents in the Setup window.
• Model
SAL18135
• Process
Service
• State
FW Unlock
4. Click
[OK].
Fig.1-5-2
5. When the window below appears. Click [Firm lock:Reset].
Fig.1-5-3
6. When the specified plug is released normally, OK is displayed.
Fig.1-5-4
Note:
The lens cannot be detected when the lens is connected to the camera without releasing the specified plug.