HELP20
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the anti-diffusion agent (A-20) to the indicated portion of focus ring.
2.
Aligning with the right end of cut portion on the top of groove of focus ring, install the focus scale plate.
Affix the polyester tape (black) 10mm cut as instructed to the location shown in figure.
Note:
• Install the focus scale plate in the direction marked with characters in the figure.
• Fix the focus scale plate with the polyester tape (black) 10mm not to loose.
20 ±2mm
Focus Ring
Cut portion
Reference position 
to winding
Groove
Focus Scale Plate
• Character direction of 
  focus scale plate
Apply the 
anti-diffusion 
agent (A-20)
(All circumference)
Polyester Tape (Black)
10mm (8x18mm)