DSLR-A100, DSLR-A100H, DSLR-A100K, DSLR-A100W (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 22

Read Sony DSLR-A100 / DSLR-A100H / DSLR-A100K / DSLR-A100W (serv.man3) Service Manual online

6-20
DSLR-A100_ADJ
Procedure of CCD AORI Checking
1. Set the Master body to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “AORI & CENTER” in adjustment menu.
3. Click “DSLR-A100” when “Please select master data” appears. (Fig. 1)
4. Click MASTER BODY “AORI & CENTER” in AORI & CENTER Adjustment menu. (Fig. 2)
(Data readout starts. During the readout, the camera releases the shutter twice.)
5. “Setting Data of master body has complete!” is displayed, data readout completed.
6. Click CHECK “AORI” and check the data.
7. Click “END” in AORI & CENTER Adjustment menu.
8. Click “END” in adjustment menu.
Note: Do not close the adjustment screen. Otherwise, the Master body data will be lost.
9. Exchange the Master camera for target camera.
10. Set the target to adjustment mode.
11. Click “AORI & CENTER” in adjustment menu.
12. Click “DSLR-A100” when “Please select master data” appears.
13. Click CHECK “AORI” in AORI & CENTER Adjustment menu.
(Checking starts. During the checking, the camera releases the shutter once and the Aori Adjustment window appears.)
14. Check the numbers displayed in Aori Adjustment window, whether value of “C” and “dPI” is in the range of standard value. (Fig. 3)
Standard value of C:
Between -30 and 30
Standard value of dPI: Between -30 and 30
Fig. 1
Fig. 2
Fig. 4
Fig. 3