6-17
DSLR-A100_ADJ
3.
Adjustment of the PI-PR
Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “PI-PR” of the adjustment menu. “Does it adjust?” appears.
3. Click “YES”.  Automatic adjustment starts.
4. The adjustment is completed when “OK” is displayed on the adjustment menu.
4.
Adjustment of the frequency for camera shaking (FREQUENCY)
Note:
 During the adjustment, put the body on a flat place and do not give it a shaking or vibration.
Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “FREQUENCY” of the adjustment menu. “Does it adjust?” appears.
3. Click “YES”.  Automatic adjustment starts.
4. The adjustment is completed when “OK” is displayed on the adjustment menu.
5.
Adjustment of the servo for camera shaking (SERVO)
Note:
 During the adjustment, put the body on a flat place and do not give it a shaking or vibration.
Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “SERVO” of the adjustment menu. “Does it adjust?” appears.
3. Click “YES”.  Automatic adjustment starts.
4. The adjustment is completed when “OK” is displayed on the adjustment menu.
6.
Adjustment of the gyro for camera shaking (GYRO)
Note:
 During the adjustment, put the body on a flat place and do not give it a shaking or vibration.
Required equipment
PC with preinstalled the DSLR-A100 adjustment program
USB cable
AC adaptor/charger (AC-VQ900AM)
Procedure of the adjustment
1. Set camera to adjustment mode.
Refer to “Starting up the DSLR-A100 adjustment program (in the adjustment mode)”.
2. Click “GYRO” of the adjustment menu. “Does it adjust?” appears.
3. Click “YES”.  Automatic adjustment starts.
4. The adjustment is completed when “OK” is displayed on the adjustment menu.