DSLR-A100, DSLR-A100H, DSLR-A100K, DSLR-A100W (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 14

Read Sony DSLR-A100 / DSLR-A100H / DSLR-A100K / DSLR-A100W (serv.man3) Service Manual online

6-12
DSLR-A100_ADJ
6. Select “DSLR-A100” from “CAMERA MODEL” in the window, according to the display.
“Please connect DSLR-A100 and click START!” appears. (Fig. 3)
7. Click the “CONNECT” button.
“FIRMWARE VERSION READ-OUT has completed!” appears. (Fig. 4)
2. Starting up the DSLR-A100 adjustment program (in the adjustment mode). Method 2
In the condition that a function button cannot be used such as Aori adjustment, start up the camera using a CF card with adjustment
program.
1. Insert the CF card with POWER switch on, no power supply (battery), and “M” mode.
2. Connect the camera and PC with the USB cord with connector.
3. Connect the AC adaptor (power supply) while pressing the lens release button.
4. Release the lens release button after access lamp lit, the camera starts from the CF card.
Frame counter will be “BBBB” and the camera starts up in adjustment mode. (Fig. 1)
Or, the display of In-F (viewfinder) becomes “ASIC 88”.
5. Same as 5, 6, 7 of the above method 1.
3. Quitting the DSLR-A100 adjusting program and cancel adjustment mode of camera
1. Click “END” in the window of the DSLR-A100 adjustment program.
2. Remove the AC adapter.
Fig. 3
Fig. 4