DSC-S5000 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-S5000 (serv.man2) Service Manual online

DSC-S5000_ADJ
5-4
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. Iris/Mechanical Shutter/Bad Pixel Adjustment
The Iris/Mechanical Shutter/Bad Pixel Adjustment order is as follows.
Small pattern box (PTB-1450) setting:
Color temperature = 3150 ± 50K
Luminance: LV12.3 ± 0.2
Adjustment order
Screen display
The adjustment finished normally.
O ADJUST IRIS OK
O Mshutter OK
O Still Pixel OK
O PreviewPixel OK
The adjustment is complete
The adjustment is finished abnormally.
X ADJUST IRIS NG
O Mshutter OK
O Still Pixel OK
O PreviewPixel OK
Malfunction of Iris adjustment
O PreviewPixel OK
O Still Pixel OK
O ADJUST IRIS OK
X Mshutter NG
O PreviewPixel OK
O Still Pixel OK
Malfunction of Mechanical 
Shutter adjustment
O ADJUST IRIS OK
X PreviewPixel NG
O Mshutter OK
O Still Pixel OK
Malfunction of Preview Pixel 
adjustment
Set the camera to the adjustment mode.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-2-1)
Press the control button “ v (Key Up)”, then Iris/Mechanical Shutter/Bad Pixel Adjustment starts.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-2-3 to 5-2-14)
In this case, confirm the adjusting environment
and readjust.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
the adjustment completion indication appears
on the screen. (Fig. 5-2-2)
In case of the adjustment is finished normally,
Turn off the power to quit the adjustment mode.
The adjustment is finished abnormally.
O ADJUST IRIS OK
X Still Pixel NG
O Mshutter OK
O PreviewPixel OK
Malfunction of Still Pixel adjust-
ment
X ADJUST IRIS NG
O Still Pixel OK
O PreviewPixel OK
X Mshutter NG
Malfunction of Iris & Mechani-
cal Shutter adjustment
X PreviewPixel NG
O Mshutter OK
O Still Pixel OK
X ADJUST IRIS NG
Malfunction of Iris & Preview 
Pixel adjustment
X Still Pixel NG
O Mshutter OK
O PreviewPixel OK
X ADJUST IRIS NG
Malfunction of Iris & Still Pixel 
adjustment
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
O Still Pixel OK
Malfunction of Iris, Mechanical 
Shutter & Preview Pixel adjust-
ment
X PreviewPixel NG
O Mshutter OK
X ADJUST IRIS NG
X Still Pixel NG
Malfunction of Iris, Preview 
Pixel & Still Pixel adjustment
X ADJUST IRIS NG
O PreviewPixel OK
X Mshutter NG
X Still Pixel NG
Malfunction of Iris, Mechanical 
Shutter & Still Pixel adjustment
X Mshutter NG
X Still Pixel NG
O ADJUST IRIS OK
X PreviewPixel NG
Malfunction of Mechanical 
Shutter, Preview Pixel & Still 
Pixel adjustment
X ADJUST IRIS NG
X Mshutter NG
X PreviewPixel NG
X Still Pixel NG
Malfunction of all adjustments
Equipment required: Small pattern box (PTB-1450)
Small pattern box
(PTB-1450)
0.5 to 1.0 cm
Black cloth
Camera
Clear chart
Fig. 5-2-1
Fig. 5-2-2
Fig. 5-2-3
Fig. 5-2-4
Fig. 5-2-5
Fig. 5-2-6
Fig. 5-2-8
Fig. 5-2-10
Fig. 5-2-12
Fig. 5-2-14
Fig. 5-2-11
Fig. 5-2-13
Fig. 5-2-7
Fig. 5-2-9
Page of 7
Display