DSC-S5000 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 6

Read Sony DSC-S5000 (serv.man2) Service Manual online

DSC-S5000_ADJ
5-6
5-2-4. Near Focus Adjustment
Note:
  Perform the Near Focus Adjustment after the Far Focus Adjustment.
1)  Be sure to set 50 ± 1 cm distance between the chart and the tip of camera lens.
2)  Check that the center of chart meets the center of shot image screen with the zoom 
lens at TELE end and WIDE end respectively.
Color temperature = 5000 ± 300K
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
O Near Focus Station Passed
Please Key MENU Enter...
The adjustment is complete
The adjustment is finished abnormally.
X Near Focus NG !
Please ReAdjust Far Focus
Malfunction of Near Focus ad-
justment
Adjustment order
Set the camera to the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Chart. (Fig. 5-2-22)
Press the control button “ B (Key Right)”, then Near Focus Adjustment starts.
on the screen. (Fig. 5-2-23)
In case of the adjustment is finished normally,
the adjustment completion indication appears
Turn off the power to quit the adjustment mode.
(Fig. 5-2-24)
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
In this case, confirm the adjusting environment
and readjust.
In case of the Near Focus adjustment is failed,
readjust the Far Focus adjustment and try to
readjust the Near Focus adjustment.
Screen display
5-2-5. White Balance Adjustment
The White Balance Adjustment is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3150 ± 50K
Luminance: LV12.3 ± 0.2
The adjustment finished normally.
O WB OK
The adjustment is complete
The adjustment is finished abnormally.
X Cap WB NG
Malfunction of Cap White Bal-
ance adjustment
X Pre WB NG
Malfunction of Pre White Bal-
ance adjustment
X WB NG
Malfunction of White Balance 
adjustment
Adjustment order
Set the camera to the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-2-25)
Press the control button “ z (Key OK)”, then White Balance Adjustment starts.
the adjustment completion indication appears
on the screen. (Fig. 5-2-26)
In case of the adjustment is finished normally,
Turn off the power to quit the adjustment mode.
the following indication appears on the screen.
(Fig. 5-2-27 to 5-2-29)
In case of the adjustment is finished abnormally,
In this case, confirm the adjusting environment
and readjust.
Screen display
Chart
Camera
Equipment required: Chart
50 ± 1 cm
Equipment required: Small pattern box (PTB-1450)
Small pattern box
(PTB-1450)
0.5 to 1.0 cm
Black cloth
Camera
Clear chart
Fig. 5-2-22
Fig. 5-2-25
Fig. 5-2-23
Fig. 5-2-24
Fig. 5-2-26
Fig. 5-2-27
Fig. 5-2-28
Fig. 5-2-29
X Need reAdjust CCD
Note:
  If this screen appears, perform the following procedure to make the 
adjustment again.
 
Readjustment restores normal state of the unit.
1.   Turn off the unit.
2.   Take the battery out of the unit.
3.   Load the battery in the unit and start the unit in the Adjustment 
mode.
4.   Make the adjustment again.
Page of 7
Display

Click on the first or last page to see other DSC-S5000 (serv.man2) service manuals if exist.