DSC-G3 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 29

Read Sony DSC-G3 (serv.man3) Service Manual online

6-28
DSC-G3_ADJ
This part indicates 
the adjustment 
item in which 
an error occurred.
4.
Adjustment NG
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
5.
Data Save Error
Symptom
The data cannot be saved normally. (The data
setting during adjustment cannot be cancelled)
Cause
• Data writing to the flash memory failed.
• Connection is faulty.
• Power supply is not installed correctly.
Remedy
• On the SeusEX Operation screen, [Set] the
data to the pages and addresses displayed in
the message, and [Save] them. (Cancel manu-
ally the data setting during adjustment.)
• Check the connection.
• Install the power supply correctly.
1-8-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not op-
erate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown figures below. Click the [Release Data Set-
ting]  button to cancel the data setting. When the data setting is
cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred, the [Release Data Set-
ting] button is displayed in “white”.
To cancel the data setting, perform it on the SeusEX Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Video System Adjustment screen
Camera System Adjustment screen
How to cancel the data setting during 
adjustment is display here.