DSC-G3 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 26

Read Sony DSC-G3 (serv.man3) Service Manual online

6-25
DSC-G3_ADJ
10-3. Preparation when the lens is replaced
Note down the PITCH/YAW and FN data on the replacement lens for
repair.
Adjustment Block
11
Adjustment Page
61
Adjustment Address
0E10, 0E11, 0E07
Note:
The PITCH/YAW and FN data of lens is written only re-
pair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
3) Read the FN data written on repair parts, and named this as
Fpy.
Fig. 6-1-23
10-4. Angular Velocity Sensor Sensitivity Adjustment
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 9, and the fol-
lowing screen will appear.
The buttons on this screen provide the following functions.
[Read] button: Reads and displays the previous data (Dp, Dy
and Fpy
*1
) from the SY-211 board.
*1: The Fpy box is displayed, when you give a check to the
check box at lower left of “Input the PITCH/YAW and FN
data”.
[Save] button: Saves the previous data (Dp, Dy and Fpy) in
the PC as a file.
[Load] button: Loads and displays the previous data (Dp, Dy
and Fpy) from the file saved in the PC.
• Default file name is as follows:
2) Input the previous data (Dp, Dy and Fpy
*1
) into screen.
If the previous data cannot be read, give a check to the checkbox
at lower left of screen.
*1: The Fpy box is displayed, when you give a check to the
check box at lower left of “Input the PITCH/YAW and FN
data”.
3) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
4) Input the PITCH/YAW and FN data of lens (L
1
, L
2
 and Fpy)
read at “Preparation” into the screen.
If the lens was not replaced, give a check to the checkbox at
the lower left of the screen.
Note:
In order to get the correct value for the adjustment, it is
necessary to input a decimal point (“period” or
“comma”) as same format as windows setting because
“Numeric Value Format” depend on the language.
(F:123 456 789,00, GB:123,456,789.00,
D:123.456.789,00)
“Numeric Value Format” setting is available in “Con-
trol Panel”-“Regional and Language Options”.
5) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
6) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
YAW data 
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
P.PP / Y.YY
FN Data
FN data 
t
 Fpy
XX
FN
L1/L2
DSC-G3_D
p
D
y
DT_xxxxxxxx_yyyymmdd.dat
Date
USB serial number
Data name
Page of 36
Display

Click on the first or last page to see other DSC-G3 (serv.man3) service manuals if exist.