CDX-GT565UV, CDX-GT615UV - Sony Car Audio Service Manual (repair manual). Page 5

Read Sony CDX-GT565UV / CDX-GT615UV Service Manual online

CDX-GT565UP/GT565UV/GT615UV
5
NOTE  FOR  REPLACEMENT  OF  THE  USB  CONNEC-
TOR (CN971)  AND  THE  AUX  JACK (J901)
To replace the USB connector and the AUX jack requires align-
ment.
1.  Insert the USB connector and the AUX jack into the front pan-
el.
2.  Place the KEY board on the front panel and align the terminals 
of the USB connector and the AUX jack with the holes in the 
KEY board.
3.  Solder seven terminals of the connector and three terminals of 
the jack.
SERVO board
(CN401)
MAIN board
(CN700)
extension cable (CD mecha)
KEY board
front panel
USB (socket) connector
AUX jack
TEST  DISCS
Use following TEST DISC (for CD) when this set confi rms  the 
operation and checks it.
Part No.
   
Description
3-702-101-01 DISC 
(YEDS-18), 
TEST
4-225-203-01 DISC 
(PATD-012), 
TEST
NOTE  FOR  REPLACEMENT  OF  THE  SERVO  BOARD
When repairing, the complete SERVO board should be replaced 
since any parts in the SERVO board cannot be repaired.
NOTE  FOR  REPLACEMENT  OF  THE  SENSOR  BOARD
When the SENSOR board is defective, exchange the MECHANI-
CAL BLOCK (Z) ASSY 08 (Former type) or MECHANICAL 
BLOCK (11CA) ASSY (New type).
Note: As for the mechanism deck (MG-101CA-188) carried in this 
unit, component parts have been changed from the midway 
of production. When you perform repair exchange of the 
mechanism deck (MG-101CA-188), refer to “ABOUT THE 
MG-101CA-188 OF FORMER AND NEW” on page 6.
CLEANING  THE  CONNECTORS
The unit may not function properly if the connectors 
between the unit and the front panel are not clean. In order 
to prevent this, detach the front panel and clean the 
connectors with a cotton swab. Do not apply too much force. 
Otherwise, the connectors may be damaged. 
Notes
t For safety, turn off the ignition before cleaning the connectors, 
  and remove the key from the ignition switch.
t Never touch the connectors directly with your fingers or with 
  any metal device.
EXTENSION  CABLE  AND  SERVICE  POSITION
When repairing or servicing this set, connect the jig cable (extension cable (CD mecha)) as shown below.
• 
Connect the MAIN board (CN700) and the SERVO board (CN401) with the jig cable.
Jig cable:
Part No.
   
Description
A-1818-424-A 
EXTENSION CABLE (CD MECHA)
Ver. 1.2
Page of 54
Display