16
Display on fl uorescent indicator tube
Description
P
R
O
C
O
U
N
T
※ ※
No of time protector happen (0 ~ 99)
P
R
O
T
Y
P
E
※ ※ ※ ※
Refer to protect type description
T
1
※ ※ ※ ※ ※
H
※ ※
M
Single Power On Time until protector happened
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
T
2
※ ※ ※ ※ ※
H
※ ※
M
Total Power On Time [ no consider protector happen ]
(0~99999 hours, 0~99Min)
(0~99999 hours, 0~99Min)
F
U
N
C
※ ※ ※ ※ ※ ※ ※
Input Function during protector happened
V
O
L
※ ※ ※
Volume setting (MIN / 1 - 50 / MAX)
A
T
T
※ ※ ※
Actual attenuation (-87 … 0)
E
Q
L
O
W
※ ※ ※
Low EQ level (-6 … 0 … +6)
E
Q
M
I
D
※ ※ ※
Mid EQ level (-6 … 0 … +6)
E
Q
H
I
G
H
※ ※ ※
High EQ level (-6 … 0 … +6)
S
U
R
R
※ ※ ※
Surround setting (OFF / ON)
D
J
※ ※ ※ ※ ※ ※
※ ※
DJ Effect setting
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
DJ Mode: OFF/ISOLAT/FLANGE/PAN/WAH
DJ Setting Value: 1~ 40
B
A
Z
U
C
A
※ ※ ※
Bass Bazuca setting (OFF / ON)
[HISTORY MODE]
This mode is used to check important data stored in the system
when PROTECTOR happen.
This mode is used to check important data stored in the system
when PROTECTOR happen.
Procedure:
1. During demo mode, press [OPTIONS]
*1
/ [X]
*2
button and
[FLANGER] button for 5 seconds to mode into history mode.
2. Press the [M >
TUNING +]
*1
/ [TUNING + >]
*2
button or [
. m TUNING ‒]
*1
/ [. TUNING ‒]
*2
button to check history data stored.
To release from History Mode.
To release from this mode, press [
To release from this mode, press [
\/1
] button.
Ver. 1.1
Note:
*1
SHAKE99 model
*2
HCDSHAKE100 model
Protect Type Description:
Error Code
Description
E01
The over current condition to MOSFET occurs
by defect of MOSFET or defect of PS output
line.
by defect of MOSFET or defect of PS output
line.
E03
Defect of power supply circuit to AMP.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
There is possibility of unusual power supply of
any of the AMP IC or Pre-amplifi er.
E04
DC appears in SP terminal by defect of AMP
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
IC and MOSFET
or
Defect of DC FAN and DC FAN driver circuit
E05
Unusual heat up of MOSFET by improper
assembly of heat sink, destruction of MOSFET
etc.
assembly of heat sink, destruction of MOSFET
etc.
If speaker does not have output even if the set status is not in
PROTECT mode, the following defect might be possible:
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.