XV-Z12000 (serv.man12). (10) Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 17

Read Sharp XV-Z12000 (serv.man12) Service Manual online

51
XV-Z12000
Select the video signal type.
Supply an NTSC3.58 VIDEO 
signal to INPUT4.
Select INPUT4 using the key on 
the main unit or the remote control.
YES
NO
Is the color normal?
Is the image frame normal?
Set the video signal system to 
Auto and see if any abnormality 
is present.
Go to "IC8338 peripheral check".
End.
Check the composite VIDEO 
(CVBS) input.
Supply an NTSC3.58 S-VIDEO 
signal to INPUT3.
Select INPUT3 using the key on 
the main unit or the remote control.
Check the S-VIDEO input.
YES
NO
Is a projection image displayed?
Is the picture distorted?
Go to "Check the VIDEO 
synchronization signal."
Select NTSC3.58 as the optional video 
signal system on the menu display.
Page of 21
Display