XV-Z12000 (serv.man12). (10) Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 12

Read Sharp XV-Z12000 (serv.man12) Service Manual online

46
XV-Z12000
Check the RGB signal.
YES
No
Set the input signal type to 
RGB.
Is the input signal type set to 
RGB?
Go to "GA4 peripheral check".
GA4 peripheral check
YES
NO
Press the key on the main unit or the 
[MENU] key on the remote control.
Is the menu display brought up?
Go to "Check OSD.".
NO
YES
Select the color bar from the 
process mode Pattern menu. 
Is the projection image displayed 
correctly?
End of "GA4 peripheral check"
Set the signal generator to output 
a RAMP signal.
NO
YES
Check FL8141 - FL8148 using an 
oscilloscope. Is a pulse being 
output?
The J5 connector or the 
formatter unit is defective.
NO
YES
Are signals present at TL8106 - 
TL8111?
IC8029 (GA4) is defective.
Go to "IC8004 peripheral check".
YES
NO
Is the CW-INDEX value shown in 
the process mode DLP menu 
within the standard value range: 
130–2?
Adjust the CW-INDEX.
Page of 21
Display

Click on the first or last page to see other XV-Z12000 (serv.man12) service manuals if exist.