XV-Z12000 (serv.man12). (10) Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 16

Read Sharp XV-Z12000 (serv.man12) Service Manual online

50
XV-Z12000
Check the input signal type.
Supply a 525i (625i) RGB (or 
component) signal to INPUT1 
or INPUT2.
Select INPUT1 or INPUT2 using 
the key on the main unit or the 
remote control.
YES
NO
Is the picture distorted?
YES
Is the color normal?
Is the image frame normal?
Perform the process adjustment. 
Does the color become normal?
Go to "GA4 
peripheral check".
Go to "IC8004 peripheral 
check".
YES
End.
YES
NO
Is a projection image displayed?
Go to "Check the SOG circuit."
NO
NO
NO
When checking the optional input signal on the menu display, 
select RGB (or component) or set it to RGB (or component) 
using the RGB/COMP key on the remote control.
Go to "Check the VIDEO 
synchronization signal."
Check the 525i (625i) RGB (or 
component) input.