PG-A20X. Version 1.5 - Sharp Projector Handy Guide. Page 15

Read Sharp PG-A20X Handy Guide online

Maintenance Procedure
Version 1.5
Issue 04/2006
15
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
Replacing the Air Filter
• 
This projector is equipped with air filters to
ensure the optimal operating condition of the
projector.
• 
The air filters should be cleaned every 100
hours of use. Clean the filters more often
when the projector is used in a dusty or smoky
location.
 
• 
Ask your nearest Sharp Authorised Projector
Dealer or Service Centre to exchange the filter
(PFILDA008WJZZ) when it is no longer
possible to clean.
1. 
Turn off the power and disconnect the power
cord.
• 
Press “OFF”. Wait until the cooling fan stops.
 
2. 
Remove the filter/lamp unit cover.
• 
Turn the projector over. Loosen the user service
screw (1) that secures the filter/ lamp unit cover.
Pressing the tab (2), remove the filter/lamp unit
cover (3).
3. 
Remove the air filter.
• 
Pick the air filter up with your fingers and lift it out of
the filter/lamp unit cover.
 
Page of 46