MX-M905 (serv.man7). Administrator machine adjustment guide. - Sharp Copying Equipment User Guide / Operation Manual. Page 9

Read Sharp MX-M905 (serv.man7) User Guide / Operation Manual online

 
 
3)  A test patch containing a column of 28 patches (3-30) is 
printed. 
 
Note: 
When the printing of a test patch fails, the following 
message appears: Printing test patch has failed. Use 
8 1/2" X 11" or A4 paper for this adjustment. Tap the 
[Execute] key to print the test patch. 
 
 
 
4)  Select the [5] or [32] keys for the number of adjustment 
points. 
 
Note: 
If you selected the [5] key, visually check the five 
points (4, 10, 16, 22, 29) on the test pattern. If you 
selected the [32] key, visually check the density of the 
28 points (3 to 30) on the test pattern. 
 
5)  Enter the desired values and tap the [Execute] key
 to 
start the adjustment. 
 
When the [5] key is selected in step 4): 
 
Input range: [25] to [75] 
Default: 50
When the [32] key is selected in step 4): 
Example of the Density Smoothing Adjustment (Visual 
Adjustment) screen 
 
Input range: [25] to [75] 
Default: 50 
 
Note: 
If you want to darken a point after checking the test 
pattern, increase the value. If you want to lighten a 
point, decrease the value. 
 
6)  When the adjustment is completed, a completion 
message appears and the adjustment result is printed. 
 
 
 
Note: 
When the printing of the adjustment result fails, the 
following message appears: Printing adjustment 
result has failed. Use 8 1/2" X 11" or A4 paper. Tap 
the [Execute] key to print the adjustment result. 
 
 When the desired density is not achieved, tap the 
[Readjust] key and repeat steps 2) to 6). 
 
 In 5-point adjustment, 5 points can be entered to 
extrapolate and adjust all of the remaining 32 points. 
 
 In 32-point adjustment, each point can be adjusted.   
 
 If you selected the [32] key, the density of 1, 2, 31, and 
32 cannot be checked on the test pattern. These values 
are the setting range for A3W. If the density is not 
uniform on A3W paper, print the test pattern on A3W 
paper and enter the values of 1, 2, 31, and 32 as 
needed. 
 
 When the desired density is achieved, tap the [Back] 
key to return to the Laser Adjustment screen. 
 
7)  Make sure to perform [1.4.3 Standard Calibration] 
under [Settings] if you wish not to erase the adjustment 
values set by [1.4.1 Gray Balance Adjustment (for 
Copy)] and [1.4.2 Gray Balance Adjustment (for Print)]) 
after this adjustment. Make sure to choose both the 
copy and printer calibrations in the calibration. 
R Side 
F Side 
R Side 
F Side 
Page of 29
Display

Click on the first or last page to see other MX-M905 (serv.man7) service manuals if exist.