Read Sharp MX-M905 (serv.man7) User Guide / Operation Manual online
8
3) A test patch containing a column of 28 patches (3-30) is
printed.
Note:
When the printing of a test patch fails, the following
message appears: Printing test patch has failed. Use
8 1/2" X 11" or A4 paper for this adjustment. Tap the
[Execute] key to print the test patch.
4) Measure the values of the five specified positions on
the test patch with the densitometer.
Note:
All five values must be entered. Adjustment is
performed by reduction of all five points.
5) Use a densitometer to measure the density of five
points (4, 10, 16, 22, 29) on the test pattern
6) Enter the density values of the five points measured
with the densitometer in the respective text boxes, and
tap the [Execute] key.
Input range: [0] to [300] (1 = 0.01)
Default: [0] for each
7) When the adjustment is completed, a completion
message appears and the adjustment result is printed.
Note:
When the printing of the adjustment results fails, the
following message appears: Printing adjustment
result has failed. Use 8 1/2" X 11" or A4 paper. Tap
the [Execute] key to print the adjustment result.
8) Check the density in the adjustment result.
When the desired density is not achieved, tap the
[Readjust] key and repeat steps 2) to 8).
When the desired density is achieved, tap the [Back]
key to return to the Laser Adjustment screen.
9) Make sure to perform [1.4.3 Standard Calibration]
under [Settings] if you wish not to erase the adjustment
values set by [1.4.1 Gray Balance Adjustment (for
Copy)] and [1.4.2 Gray Balance Adjustment (for Print)])
after this adjustment. Make sure to choose both the
copy and printer calibrations in the calibration.
1.1.3 Density Smoothing Adjustment (Visual
Adjustment)
This performs density smoothing adjustment for printing in
front / rear (main scan) direction by measuring test patch
visually.
1) Select the [Visual Adjustment] key in the Laser
Adjustment screen.
2) To print a test patch, tap the [Execute] key in the
Density Smoothing Adjustment (Visual Adjustment)
screen. If you need to change the density, select the
desired density and then tap the [Execute] key.
Note:
To return your preferences to the factory defaults, tap
the [Return to the Defaults (Density Smoothing
Adjustment)] key. When a confirmation message
appears, tap the [OK] key. The machine reboots to
return to the factory defaults.
R Side
F Side
R Side
F Side
Click on the first or last page to see other MX-M905 (serv.man7) service manuals if exist.