Read Sharp MX-M905 (serv.man7) User Guide / Operation Manual online
6
Machine Adjustment
1 Image Quality Adjustment
Select the [Image Quality Adjustment] key in the Machine
Adjustment screen.
1.1
Laser Adjustment
Select the [Laser Adjustment] key in the Image Quality
Adjustment screen.
1.1.1 Density Smoothing Adjustment (Auto
Adjustment)
This performs density smoothing adjustment for printing in
front / rear (main scan) direction automatically.
1) Select the [Auto Adjustment] key in the Laser
Adjustment screen.
2) To print a test patch, tap the [Execute] key in the
Density Smoothing Adjustment (Auto Adjustment)
screen. If you need to change the density, select the
desired density and then tap the [Execute] key.
Before and after Density Smoothing Adjustment
(Auto Adjustment)
[Before Adjustment]
The density of the test pattern is not uniform
[After Adjustment]
The density is smoothed
3) A message “Value set at Density Smoothing
Adjustment (Densitometer/Visual) is cleared if executed.
Execute?” comes up when you tap the [Execute] key.
Tap the [Execute] key to continue if you do not see a
problem. Tap the [Cancel] key if you do not want to
clear the value.
Note:
To return your preferences to the factory defaults, tap
the [Return to the Defaults (Density Smoothing
Adjustment)] key. When a confirmation message
appears, tap the [OK] key. The machine reboots to
return to the factory defaults.
Click on the first or last page to see other MX-M905 (serv.man7) service manuals if exist.