Read Sharp MX-M905 (serv.man2) Service Manual online
MX-M905 SIMULATION 6 – 2
4. List of simulation codes
A. List of classic mode
Main
Sub
Function (Purpose)
Section
Purpose
1
1
Used to check the operation of the scanner (reading) unit and the control circuit.
Scanner (reading)
Operation test/check
2
Used to check the sensors in the scanner (reading) section and the related circuits.
Scanner (reading)
Operation test/check
5
Used to check the operation of the scanner (reading) unit and the control circuit.
Scanner (reading)
Operation test/check
2
1
Used to check the operations of the auto document feed unit and the control circuits.
DSPF
Operation test/check
2
Used to check the operations of the sensors and detectors in the auto document feed unit and
the control circuits.
the control circuits.
DSPF
Operation test/check
3
Used to check the operations of the loads in the auto document feed unit and the control circuit.
DSPF
Operation test/check
6
Used to check the operation of the scanner fan motor.
Scanner (reading)
Operation test/check
3
2
Used to check the operations of the sensors and the detectors in the finisher and the control
circuits.
circuits.
Finisher
Operation test/check
3
Used to check the operations of the motors and the solenoids in the finisher and the control
circuits.
circuits.
Finisher
Operation test/check
10
Used to adjust the jogger position, the lead edge stopper position, the staple jogging count
number, and the paper folding count number.
number, and the paper folding count number.
Finisher
Finisher adjustment
30
Used to check the operations of the sensors and the detectors in the inserter and the related
circuits.
circuits.
Inserter
Operation test/check
31
Used to check the operations of the loads in the inserter and the control circuits.
Inserter
Operation test/check
40
Used to check the operations of the sensors and the detectors in the paper folding unit and the
related circuits.
related circuits.
Paper folding unit
Operation test/check
41
Used to check the operations of the motors and the solenoids in the paper folding unit and the
control circuits.
control circuits.
Paper folding unit
Operation test/check
42
Paper folding unit adjustment
Paper folding unit
Adjustment
50
Decurler sensor check
Decurler
Operation check
51
Decurler individual load check
Decurler unit
Operation check
4
2
Used to check the operations of the sensors and the detectors in the large capacity tray (LCC)
and the control circuits.
and the control circuits.
Large capacity tray
(LCC)
(LCC)
Operation test/check
3
Used to check the operations of the loads in the desk/large capacity tray (LCC) and the control
circuits.
circuits.
Desk/Large capacity
tray
tray
Operation test/check
5
Used to check the operations of the transport clutch (LTRC) in the LCC and the monitor.
Large capacity tray
(LCC)
(LCC)
Operation test/check
10
LCT warm air heater temperature setting
LCT
Setting
11
LCT fan Duty setting
LCT
Setting
14
LCT temperature and humidity sensor monitor display
LCT
Check
5
1
Used to check the operations of the display lamp and the LCD on the operation panel and the
control circuit.
control circuit.
Operation panel
Operation test/check
2
Used to check the operation of the heater lamp and the control circuit.
Fusing
Operation test/check
3
Used to check the operations of the copy lamp and the control circuit.
Scanner/DSPF
(reading)
(reading)
Operation test/check
4
Used to check the operations of the discharge lamp and the control circuit.
Process
Operation test/check
6
1
Paper transport,
paper exit
paper exit
Operation test/check
2
Used to check the operations of each fan motor and the control circuit.
Operation test/check
3
Used to check the operations of the primary transfer separation.
Process (transfer)
Operation test/check
4
Used to check the operation of the MC cleaner.
Process (charging)
Operation test/check
90
Used to reset the machine to the factory setting. (The scanner is set to the lock enable position)
Scanner
Setting
7
1
Used to set the conditions of aging operation.
Setting
6
Used to set the intermittent aging cycle.
Setting
8
Used to display the warm-up time.
Operation display
12
Used to set the document scan quantity. (For development and inspection)
Operation test, check
8
1
Used to check and adjust the developing voltage in each print mode and the control circuit.
Process
(Development)
(Development)
Operation test/check/
adjustment
adjustment
2
Used to check and adjust the operations of the main charger grid voltage in each print mode and
the control circuit.
the control circuit.
Process
Operation test/check/
adjustment
adjustment
6
Used to check and adjust the operation of the transfer plus bias current and the control circuit.
Process (transfer)
Operation test/check/
adjustment
adjustment
9
2
Used to check the operations of the sensors and detectors in the paper reverse section (duplex
section) and its control circuit.
section) and its control circuit.
Duplex
Operation test/check
3
Used to check the operations of the load in the paper reverse section (duplex section) and its
control circuit.
control circuit.
Duplex
Operation test/check
10
1
Used to check the operation of the toner motor and the control circuit.
Process
(Development)
(Development)
Operation test/check
2
Used to check the operation of the toner hopper empty sensor.
Process
(Development)
(Development)
Operation test/check
4
Use to check the toner cartridge motor rotation sensor.
13
-
Used to cancel the self diag U1 trouble.
Cancel (trouble, etc.)
14
-
Used to cancel the self diag H3/H4/H5 troubles.
Fusing
Cancel (trouble, etc.)
15
-
Use to cancel the trouble (F3-12,22/U6-09,29,39,63,69)
LCC
Cancel (trouble, etc.)
16
-
Used to cancel the self diag U2 trouble.
MFPcnt PWB/PCU
PWB/SCU PWB
PWB/SCU PWB
Cancel (trouble, etc.)