Read Sharp MX-M905 (serv.man16) Regulatory Data online
PIS Ver1.0 2014-06
SHARP CORPORATION
PRODUCT INFORMATION SHEET (PIS)
Model:
MX-M905
Issued Date:
2017/1/27
Revised Date:
1. Certificates
- Environmental certificates :
Energy Star (version 2.0)
Certified
Blue Angel (RAL-UZ 171)
No plan
Nordic Ecolabel (version 6)
No plan
- Safety certificates :
CE, GS, SEMKO
- ISO certificates of factory :
ISO 9001, ISO 14001
2. Energy
Power Consumption
Heat (released)
- Maximum power consumption :
2,300 W
8,280 kJ/h
- Operating mode :
1)
1,696 W
6,106 kJ/h
- Ready mode :
1)
302 W
1,087 kJ/h
- Preheat mode (Low power mode) :
1)
286 W
1,030 kJ/h
- Auto power shut-off mode (Sleeep mode) :
1)
1.1 W
4.0 kJ/h
- Plug-in off mode :
1)
0.2 W
0.7 kJ/h
- TEC value (Weekly Consumption) :
2)
12.4 kWh
---
3. Chemical Emission
- TVOC :
- Colour mode
1)
--- mg/h
- Monochrome mode
1)
1.3 mg/h
- Benzene :
- Colour mode
1)
--- mg/h
- Monochrome mode
1)
<LOD mg/h
- Styrene :
- Colour mode
1)
--- mg/h
- Monochrome mode
1)
<LOD mg/h
- Ozone :
- Colour mode
1)
--- mg/h
- Monochrome mode
1)
1.4 mg/h
- Dust :
- Colour mode
1)
--- mg/h
- Monochrome mode
1)
<LOD mg/h
"< LOD" means Less than limit of detection.
4. Noise Emission
- Sound power level (L
W Ad
)
:
- Declared A-weighted
1)
73.8 dB
- Operating (*)
3)
7.9 B
- Standby
3)
5.9 B
- Sound pressure level (L
p Am
): - Operating (*)
3)
60.9 dB
(Bystander positions)
- Standby
3)
40.6 dB
(*) Measurement Configuration
MX-FN21 + MX-RB18
5. Other
The SDS (Safety Data Sheet) can be viewed at the following URL address:
http://www.sharp-world.com/corporate/eco/env-info/sds/us/index.html
Note
- Measurement conditions :
- Voltage
230 V
- Frequency
50 Hz
1) The value is measured in accordance with the method specified in Blue Angel RAL-UZ 122.
2) The value is measured in accordance with ENERGY STAR Program Requirements for Imaging Equipment Version 2.0.
3) The valus is measured in accordance with the method specified in ISO 7779:2010.
2) The value is measured in accordance with ENERGY STAR Program Requirements for Imaging Equipment Version 2.0.
3) The valus is measured in accordance with the method specified in ISO 7779:2010.
Main unit with option
The above values are the values which were used for the application of environmental labels, and don't guarantee for all products.
Display