Read Sharp MX-M905 (serv.man2) Service Manual online
MX-M905 ADJUSTMENTS 5 – 83
ADJ 17
Touch panel coordinate
adjustment
adjustment
This adjustment is required in the following cases:
* When the operation panel is replaced.
* When the U2 trouble occurs.
* When the scanner control PWB is replaced.
* When the EEPROM on the scanner control PWB is replaced.
1)
Enter the Sim. 65-1 mode.
2)
Touch the four cross marks on the corners precisely. Do not
use a finger.
use a finger.
When the cross marks are touched precisely, they are
reversely displayed. When the touch panel adjustment is com-
pleted by touching all the four marks, the display returns to the
sub code entry menu.
reversely displayed. When the touch panel adjustment is com-
pleted by touching all the four marks, the display returns to the
sub code entry menu.
Note:
When touching the cross marks, never use a sharp tip (such
as a needle and a pin).
as a needle and a pin).
ADJ 18
Waste toner detection level
adjustment
adjustment
This adjustment is required in the following cases:
* The waste toner detection section has been disassembled.
* One or more parts of the waste toner detection section have
been replaced.
Turn the waste toner detection adjustment knob so that height from
upper surface of the adjustment knob to head edge of the tension
bar is 2.0 mm.
upper surface of the adjustment knob to head edge of the tension
bar is 2.0 mm.
ADJ 19
Fusing paper guide position
adjustment
(Manual adjustment of fusing
paper guide position)
adjustment
(Manual adjustment of fusing
paper guide position)
This adjustment is required in the following cases:
* When a paper jam occurs in the fusing section.
* When the lead edge of paper is folded in the fusing section.
* When skew is generated in the fusing section.
* When blur or improper focusing is generated on the lead edge
section or the rear edge section of an image on paper.
* When wrinkle is generated on paper.
1)
Remove the fusing unit.
2)
Loosen the screw.
3)
Slide the fusing paper guide up or down to adjust the position.
* Check and mark the scale position before the adjustment
(with a pencil, etc.), and slide to the left and the right evenly.
2mm