Read Sharp MX-M904 / MX-M1204 (serv.man9) Service Manual online
MX-M1204 MX-FN21/FN22 (FINISHER/SADDLE STITCH FINISHER) 18 – 7
I.
Cable connection
1)
Insert the wire saddle (Packed items No.4) into the hole in the
upper rear cover to attach.
upper rear cover to attach.
2)
Attach the interface cable to the wire saddle. (The figure below
shows that the cable is wound two turns and fixed.)
shows that the cable is wound two turns and fixed.)
3)
Connect the AC cable.
J. Staple position label attachement
1)
Attach the staple position label (Packed items No.11, 12) to the
position indicated in the figure.
position indicated in the figure.
For scanner
For DSPF
Cleaning of the document scan section
CAUTION
When streaks appear on copy or scan
images, open the automatic document
feed unit and clean the document scan
section with the glass cleaner (accessory).
Click on the first or last page to see other MX-M904 / MX-M1204 (serv.man9) service manuals if exist.