MX-M1100  FUSING SECTION  N – 7
4)
Remove the clip (a), and pull out the shaft (b). Open the paper
gude (c).
5)
Remove the terminal (a). Remove the screw (b) and the
washer (c). Remove the thermostat (d).
* Insert the terminal (a) fully to the bottom until it clicks. Check
to confirm that it is securely connected. 
e. Lower pawl separation solenoid
1)
Remove the fusing unit.
2)
Remove the screw (a) and the cover (b). Remove the harness
from the edge saddle (c). Remove the snap band (d) and dis-
connect the connector (e).
Remove the screw (f), and remove the lower heat roller sepa-
ration pawl unit (g). 
3)
Remove the  screw (a) and remove the lower pawl separation
solenoid (b).
b
c
a
a
a
b
c
d
c
a
a
b
e
d
f
g