MX-M623U, MX-M753U (serv.man10). COMPLETE SERVICE MANUAL - Sharp Copying Equipment Service Manual (repair manual). Page 117

Read Sharp MX-M623U / MX-M753U (serv.man10) Service Manual online

MX-M753N  SIMULATION  6 – 21
 
24-30
Purpose
Data clear
Function (Purpose) Used to initialize the administrator pass-
word.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The administrator password is initialized.
If the administrator password of system setting and Web page is
forgotten, execute this simulation to set the password to "admin"
(default).
 
24-31
Purpose
Data clear
Function (Purpose) Used to initialize the service mode (Web
page) password.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The service mode password is initialized.
If the password of Web page is forgotten, execute this simulation to
set the password to "service" (default).
 
25
 
25-1
Purpose
Operation test/check
Function (Purpose) Used to check the operations of the devel-
oping section, and to display the toner den-
sity detection level.
Section
Process (Developing section)
Operation/Procedure
1)
Select the process speed with the touch panel key.
2)
Press [EXECUTE] key.
The developing motor and the OPC drum motor rotate for 3
minutes and the output level of the toner density sensor is dis-
played.
 
25-2
Purpose
Setting
Function (Purpose) Used to make the initial setting of toner
density when replacing developer. (Auto-
matic adjustment)
Section
Process (Photoconductor/Developing/
Transfer/Cleaning)
Operation/Procedure
1)
Press [EXECUTE] key.
The developing motor rotates for 3 minutes, and the toner density
sensor makes sampling of the toner density. The detected level is
displayed.
After stopping the developing motor, the average value of the toner
density sampling results is set as the reference toner density con-
trol level.
NOTE: When the above operation is interrupted on the way, the
reference toner concentration level is not set. Also when
error code of EE-EC, EE-EL or EE-EU is displayed, the ref-
erence toner density level is not set normally.
Do not execute this simulation unless new Developer material has
been installed. If it is executed in other cases, under toner or over-
tone may occur, causing a trouble.
Adjustment result data display
Data display during execution
Display in case of an error
 
26
 
26-2
Purpose
Setting
Function (Purpose) Used to set the paper type and the weight
type.
Section
Paper feed
Operation/Procedure
Select a paper size to be changed with the touch panel.
LOW
Process speed: Low speed
MIDDLE
Process speed: Medium speed
TCS
Toner density detection level
TCV_K
Toner density sensor output voltage level
Item/Display
Content
AUTO DV(L)
Toner density adjustment value at the low speed
AUTO DV(M)
Toner density adjustment value at the middle speed
AUTO DV VO(L)
Toner density sensor control voltage level at the low 
speed
AUTO DV VO(M)
Toner density sensor control voltage level at the 
middle speed
Item/Display
Content
TCS
Toner density sensor detection level
TCV
Toner density sensor control voltage level
Error display
Content
Details of content
EE-EL
EL abnormality
Sensor output level less than 26, or 
sensor control voltage level over 197
EE-EU
EU abnormality
Sensor output level over 200, or sensor 
control voltage level less than 49
EE-EC
EC abnormality
The sampling level in the automatic 
toner density adjustment is outside of 
108 
 5.
TRAY2
0
8.5 x 11
1
A4
2
B5
A4 LCC
0
8.5 x 11
1
A4
2
B5
G/LBS SET
0
GRAM
1
LBS
Page of 127