MX-M565N ADJUSTMENTS AND SETTINGS 4 – 9
6)
Change the set value of set item A.
When the set value is changed by 1, the dimension is changed
by 0.1mm.
by 0.1mm.
When the set value is increased, the BK image magnification
ratio in the main scanning direction is increased. When the set
value is decreased, the BK image magnification ratio in the
main scanning direction is decreased.
ratio in the main scanning direction is increased. When the set
value is decreased, the BK image magnification ratio in the
main scanning direction is decreased.
Repeat procedures 2) - 6) until a satisfactory result is obtained.
3-C
Print engine print area (void area)
adjustment
adjustment
This adjustment is needed in the following situations:
* When the LSU is replaced or removed.
* When a paper tray is replaced.
* When the paper tray section is disassembled.
* When the manual feed tray is replaced.
* When the manual feed tray is disassembled.
* When the duplex section is disassembled.
* When the duplex section is installed or replaced.
* When the large capacity paper feed tray is installed or replaced.
* When the large capacity paper feed tray section is disassembled.
* When the registration roller section is disassembled.
* U2 trouble has occurred.
* The PCU PWB has been replaced.
* The EEPROM of the PCU PWB has been replaced.
(Note)
Before executing this adjustment, be sure to execute ADJ 3B print
engine image magnification ratio adjustment (Main scanning direc-
tion) in advance.
engine image magnification ratio adjustment (Main scanning direc-
tion) in advance.
1)
Enter the SIM 50-10 mode.
2)
Set A4 (11" x 8.5") paper to all the trays, and select the set
item J with the scroll key. Enter the value corresponding to the
adjustment target paper feed tray.
item J with the scroll key. Enter the value corresponding to the
adjustment target paper feed tray.
3)
Press [EXECUTE] key.
The adjustment pattern is printed.
4)
Check the adjustment pattern to confirm that the items below
are in the range of the standard values.
are in the range of the standard values.
If the above condition is not satisfied, or if it is set to a desired
condition, execute the simulation 50-1.
condition, execute the simulation 50-1.
(Note) Feed paper from all the paper feed trays to confirm.
5)
Enter the SIM 50-1 mode.
6)
Select the adjustment item I, J, K with the scroll key, and enter
the adjustment value and press [OK] key.
the adjustment value and press [OK] key.
Content
Standard adjustment value
X
Lead edge void area
4.0
1.0mm
Y
Rear edge void area
2.0 - 5.0mm
Z1/Z2
FRONT/REAR void area
2.0
2.0mm
S I MU L A TI O N NO . 50 - 1 0
0
T E S T
C L OS E
: B K- M AG
: M A IN - MF T
: M A IN - CS 1
: M A IN - CS 2
: M A IN - CS 3
: M A IN - CS 4
: M A IN - LC C
: M A IN - AD U
: S UB - MF T
: S U B- D SK
: S U B- C S1
P A PE R C E NT E R O F FS E T S E TU P
11 6
A
[ 6 0 ~ 1 4 0 ]
A: 1 1 6
: S U B- L CC
B: 6 0
C: 6 0
D: 6 0
E: 6 0
F: 6 0
G: 6 0
H: 4 2
I: 6 0
J: 6 0
K: 6 0
L: 6 0
O K
E X EC U TE
10 K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
1 0K E Y
10 K E Y
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
BA C K
S T AR T
E XI T
C LE A R
Item/Display
Content
Setting
range
Default
value
A
Lead
edge
adjust-
ment
value
edge
adjust-
ment
value
RRCA
Document lead edge
reference position
(OC)
reference position
(OC)
0 - 99
50
B
RRCB-CS1
Resist
motor ON
timing
adjust-
ment
motor ON
timing
adjust-
ment
Standar
d Tray
d Tray
1 - 99
60
C
RRCB-DSK
Desk
1 - 99
60
D
RRCB-LCC
LCC
1 - 99
60
E
RRCB-MFT
Manual
paper
feed
paper
feed
1 - 99
60
F
RRCB-ADU
ADU
1 - 99
60
G
Image
loss area
setting
value
loss area
setting
value
LEAD
Lead edge image
loss area setting
loss area setting
0 - 99
40
H
SIDE
Side image loss area
adjustment
adjustment
0 - 99
20
I
Void area
adjust-
ment
adjust-
ment
DENA
Lead edge void area
adjustment
adjustment
1 - 99
40
J
DENB
Rear edge void area
adjustment
adjustment
1 - 99
30
K
FRONT/
REAR
REAR
FRONT/REAR void
area adjustment
area adjustment
1 - 99
20
L
Off-center
adjust-
ment
adjust-
ment
OFFSET_
OC
OC
OC document off-
center adjustment
center adjustment
1 - 99
50
M
Magnifi-
cation
ratio
correction
cation
ratio
correction
SCAN_
SPEED_OC
SPEED_OC
SCAN sub scanning
magnification ratio
adjustment (CCD)
magnification ratio
adjustment (CCD)
1 - 99
50
X
Y
Z2
2.0
2.0
4.0
1.0mm
2.0 - 5.0mm
Z1
2.0
2.0
2.0mm
2.0mm
S I MU L A TI O N NO . 50 - 0 1
0
T E S T
C L OS E
: R RC A
: R R CB - CS 1
: R R CB - DS K
: R R CB - LC C
: R R CB - MF T
: R R CB - AD U
: L E AD
: S I DE
: D EN A
: F R ON T /R E A R
: D E NB
L E AD ED G E A D JU S TM E NT V AL U E
5 0
A
[ 0 ~ 9 9 ]
A: 5 0
: O F FS E T_ O C
B: 6 0
C: 6 0
D: 6 0
E: 6 0
F: 6 0
G: 4 0
H: 2 0
I: 4 0
J: 3 0
K: 2 0
L: 5 0
O K
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
1 0K E Y
1 0K E Y
10 K EY
10 K EY
1 0 KE Y
4
5
6
1
2
3
7
8
9
*
0
#
B A C K
S T AR T
EX I T
C LE A R
Click on the first or last page to see other MX-M364N / MX-565N (serv.man4) service manuals if exist.