MX-M266N, MX-M316N, MX-M356N (serv.man3). NOTE Service Manual for models with the V suffix. - Sharp Copying Equipment Service Manual (repair manual). Page 112

Read Sharp MX-M266N / MX-M316N / MX-M356N (serv.man3) Service Manual online

MX-M356NV  SIMULATION  6 – 33
 
27-13
Purpose
Others
Function (Purpose) Used to check the history of paper transport
time between sensors. (FSS function)
Section
Operation/Procedure
Change the display with scroll key.
 
27-14
Purpose
Setting
Function (Purpose) Used  to  set  the  FSS  function  connection
test mode.
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key.
The set value in step 1) is saved.
 
27-15
Purpose
Operation test/check
Function (Purpose) Used to display the FSS connection status.
Section
Operation/Procedure
The FSS operating status is displayed.
Item/Display
Content
Occurrence date
Code between 
sensors
Passing time
Reference 
passing time
RSPF
FEED TIME1 (SPF)
History of paper transport time between SPF 
sensors 1
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME2 (SPF)
History of paper transport time between SPF 
sensors 2
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME3 (SPF)
History of paper transport time between SPF 
sensors 3
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME4 (SPF)
History of paper transport time between SPF 
sensors 4
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME5 (SPF)
History of paper transport time between SPF 
sensors 5
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME6 (SPF)
History of paper transport time between SPF 
sensors 6
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME7 (SPF)
History of paper transport time between SPF 
sensors 7
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME8 (SPF)
History of paper transport time between SPF 
sensors 8
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME9 (SPF)
History of paper transport time between SPF 
sensors 9
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME10 (SPF)
History of paper transport time between SPF 
sensors 10
Year/month/day 
hour: min.: sec.
5 digits
5 digits (ms)
5 digits (ms)
0
Disable (Default)
1
Enable
Item/Display
Content
Setting range
Default 
value
FSS CONNECTION
Used to display the 
FSS connection 
status.
0
Not 
operated
0
1
Operated
Page of 127
Display