MX-FX11 (serv.man5). Revised December 2010 - Sharp Copying Equipment Service Manual (repair manual). Page 5

Read Sharp MX-FX11 (serv.man5) Service Manual online

MX-FX11  FAX SOFTWARE SWITCH  2 – 1
MX-FX11
Service Manual
 
[2] FAX SOFTWARE SWITCH
1. List
*2: Not used in the MX-2310U.
*3: Not used in the MX-2610N/3110N/3610N.
Lines
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
1
1-8
Country code
Control is performed according to the set country code.
The destination setting that is set in SIM66-2 as the image send function is 
reflected.
The country code setting cannot be directly made from this SW.
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
2
1-4
Calling
Make time (10PPS) 
setting
Setting of make time when dialling at 10PPS.
Make time can be set from 29 to 44ms in 1ms increments by binary inputting N 
over the range of 0 to 15 (N + 29ms).
Adjustment value
5-8
Calling
Break time setting 
(10PPS) 
Setting of break time when dialling at 10PPS. 
Break time can be set from 56 to 71ms by in 1ms increments binary inputting N 
over the range of 0 to 15 (N + 56ms).
Adjustment value
3
1-4
Calling
Minimum pause time 
(10PPS) setting
Setting of minimum pause time when dialling at 10PPS.
Minimum pause time can be set from 800 to 950ms in 10ms increments by 
binary inputting N over the range of 0 to 15 (N x 10ms + 800ms).
Adjustment value
5-8
Calling
Minimum pause time 
(20PPS) setting
Setting of minimum pause time when dialling at 20PPS.
Minimum pause time can be set from 450 to 600ms in 10ms increments by 
binary inputting N over the range of 0 to 15 (N x 10ms + 450ms).
Functions only in China and Thailand.
Adjustment value
4
1-4
Calling
Make time (20PPS) 
setting
Setting of make time when dialing at 20PPS.
Make time can be set from 9 to 24ms by binary inputting N over the range of 0 
to 15 (N + 9ms).
Functions only in China and Thailand.
Adjustment value
5-8
Calling
Break time setting 
(20PPS)
Setting of break time when dialing at 20PPS.
Break time can be set from 26 to 41ms by binary inputting N over the range of 0 
to 15 (N + 26ms).
Functions only in China and Thailand.
Adjustment value
5
1-4
Calling
Setting of DTMF send 
level (high group)
This sets the send level of high area and low area DTMF signals in units of 1dB.
Setting can be made over the range of 0dB to 15dB in 1dB increments by 
binary inputting.
Adjustment value
5-8
Not used
6
1-4
Calling
Setting of DTMF send 
level (low group)
High group - Low 
group: level difference
This sets the difference between the DTMF signal high area level and low area 
level in units of 0.5dB.
Setting can be made over the range of -2.0dB to 5.5dB in 0.5dB increments by 
binary inputting. 
High group - Low group
"0 0 0 0": -2.0dB
"1 0 0 0": 2.0dB
"0 0 0 1": -1.5dB
"1 0 0 1": 2.5dB
"0 0 1 0": -1.0dB
"1 0 1 0": 3.0dB
"0 0 1 1": -0.5dB
"1 0 1 1": 3.5dB
"0 1 0 0": 0.0dB
"1 1 0 0": 4.0dB
"0 1 0 1": 0.5dB
"1 1 0 1": 4.5dB
"0 1 1 0": 1.0dB
"1 1 1 0": 5.0dB
"0 1 1 1": 1.5dB
"1 1 1 1": 5.5dB
Adjustment value
5-8
Not used
7
1-8
Calling
Setting of DTMF 
minimum pause time
This sets the minimum pause time between DTMF signals when sending DTMF 
signals.
Minimum pause time can be set by binary inputting N over the range of 0 to 255 
(1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms increments by 
binary inputting.
When SW15-3,4 are set to other than "MODEM fixed," the set value less than 
54ms is considered as 54ms.
The initial value is reverted to if a value outside of the setting range is set.
Adjustment value
Page of 57