Read Sharp MX-FX11 (serv.man5) Service Manual online
MX-FX11 FAX SOFTWARE SWITCH 2 – 4
16
1, 2
Calling
Upper limit of busy
tone ON detection time
tone ON detection time
This sets the upper limit time of the ON section when detecting frequency of the
busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
Adjustment value
3, 4
Calling
Lower limit of busy
tone OFF detection
time
tone OFF detection
time
This sets the lower limit time of the OFF section when detecting frequency of
the busy tone signal.
If busy tone OFF signals are not detected in excess of this time, do not count as
1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
the busy tone signal.
If busy tone OFF signals are not detected in excess of this time, do not count as
1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
Adjustment value
5, 6
Calling
Upper limit of busy
tone OFF detection
time
tone OFF detection
time
This sets the upper limit time of the OFF section when detecting frequency of
the busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
the busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
Adjustment value
7, 8
Not used
17
1-4
Call arrival
Call signal OFF non-
detection time
detection time
This sets the time for ignoring OFF signals and regarding ON time to be
continuous following ON detection of the call signal (CI).
This is intended to treat the PBX call signal "ring-ring" as a single call signal.
Setting can be made over the range of 0ms to 1500ms in 100ms increments by
binary inputting.
continuous following ON detection of the call signal (CI).
This is intended to treat the PBX call signal "ring-ring" as a single call signal.
Setting can be made over the range of 0ms to 1500ms in 100ms increments by
binary inputting.
Adjustment value
5-8
Call arrival
Lower limit of call
signal ON time
signal ON time
This sets the minimum ON time for detecting call signal (CI) pulses (number of
pulses). 1 pulse is counted if the CI signal remains ON for the set ON time or
longer.
Setting can be made over the range of 150ms to 300ms in 10ms increments by
binary inputting.
pulses). 1 pulse is counted if the CI signal remains ON for the set ON time or
longer.
Setting can be made over the range of 150ms to 300ms in 10ms increments by
binary inputting.
Adjustment value
18
1-4
Call arrival
Upper limit of call
signal ON time
signal ON time
This sets the maximum ON time for detecting call signal (CI) pulses (number of
pulses). Disregard and do not count as 1 pulse if the CI signal remains ON for
the set ON time or longer.
Setting can be made over the range of 3000ms to 4500ms in 100ms
increments by binary inputting.
pulses). Disregard and do not count as 1 pulse if the CI signal remains ON for
the set ON time or longer.
Setting can be made over the range of 3000ms to 4500ms in 100ms
increments by binary inputting.
Adjustment value
5-8
Call arrival
Lower limit of call
signal OFF time
signal OFF time
This sets the minimum OFF time for detecting call signal (CI) pulses (number of
pulses). 1 pulse is counted if the CI signal remains OFF for the set OFF time or
longer.
Setting can be made over the range of 100ms to 1500ms in 100ms increments
by binary inputting.
Setting range
When 0 is set, initial value 700ms operation takes place.
pulses). 1 pulse is counted if the CI signal remains OFF for the set OFF time or
longer.
Setting can be made over the range of 100ms to 1500ms in 100ms increments
by binary inputting.
Setting range
When 0 is set, initial value 700ms operation takes place.
Adjustment value
19
1, 2
Call arrival
Upper limit of call
signal OFF time
signal OFF time
This sets the maximum waiting time from detection of the call signal (CI) pulse
(number of pulses) to detection of the next CI signal pulse.
Accordingly, if the next CI signal pulse is not detected within this time, the
number of calls up to now is cleared.
"00": 6.5 seconds
"01": 10 seconds
"10": 15 seconds
"11": 20 seconds
(number of pulses) to detection of the next CI signal pulse.
Accordingly, if the next CI signal pulse is not detected within this time, the
number of calls up to now is cleared.
"00": 6.5 seconds
"01": 10 seconds
"10": 15 seconds
"11": 20 seconds
Adjustment value
3
Call arrival
CI clear judgment
Setting of the judgment of CI signal 1 cycle.
"1": Cleared only when the max. cycle is exceeded. (The min. cycle is 0.)
"0": Cleared when outside the range of 1 cycle. (The min. and the max. cycles
are set with other soft switches.)
"1": Cleared only when the max. cycle is exceeded. (The min. cycle is 0.)
"0": Cleared when outside the range of 1 cycle. (The min. and the max. cycles
are set with other soft switches.)
4, 5
Call arrival
Filter time when the CI
signal is detected.
signal is detected.
The detection sampling time of the CI signal is set in the CI signal detection
setting.
"00": 10ms
"01": 5ms
"10": 15ms
"11": 20ms
setting.
"00": 10ms
"01": 5ms
"10": 15ms
"11": 20ms
6-8
Not used
20
-
23
1-8
Not used
SW
No.
No.
Bit
No.
Item
SW selection and function
System settings
Click on the first or last page to see other MX-FX11 (serv.man5) service manuals if exist.