MX-C250, MX-C250E, MX-C250F, MX-C250FE, MX-C250FR, MX-C300F, MX-C300W, MX-C300WE, MX-C300A, MX-C300WR (serv.man6). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 119

Read Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual online

MX-C250  SIMULATION  6 – 41
10
Process control 
conditions set-
ting
DAY
When the next warm-up if there is no 
color job after a color job after pass-
ing the specified days from execution 
of the previous color process control
Disable of the speci-
fied days judgment
0 - 999
0
1
1 - 999 days passing
999
11
HI-COV
Setting of the execution judgment of the process control in 
continuous printing of high print ratio images
0 - 2
0
12
LO-COV
Setting of the execution judgment of the process control in 
continuous printing of low print ratio images
0 - 1
0
13
REV1_SH
When the accumulated traveling distance of K or M OPC 
drum unit reaches the specified level after turning ON the 
power.
0 - 1
1
14
REV2_BK_SH
When the accumulated traveling distance of K OPC drum 
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
15
REV2_CL_SH
When the accumulated traveling distance of M OPC drum 
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
16
AVERAGE-PAGE
Setting of the number of pages of item HI-COV set value 2
1 - 10
3
17
LIMIT PAGE
Setting of the number of connected jobs of the process con-
trol and of the limit number of the process control
1 - 10
10
18
PIX_RATIO_BK
Variable magnification ratio setting (%) of the BK toner count 
specified value 
The set value of 100 corresponds to K print of A4 at the print 
ratio of 5%.
1 - 999
10
19
PIX_RATIO_CL
Variable magnification ratio setting (%) of the color (CMY) 
toner count specified value
The set value of 100 corresponds to K print of A4 at the print 
ratio of 5%.
1 - 999
10
20
INTERVAL TIME
Setting of the leaving time when turning ON the power 
(including the sleep recovery time) (h: hour)
1 - 255
3
21
HUM HOUR
Interval setting of the temperature and humidity monitoring 
time of "HUM" (unit: 10 minutes)
1 - 24
2
22
HUM_DIF
The specified value of the area difference in humidity 
between the level at execution of the previous control and the 
current humidity (Applied to item HUM)
1 - 9
2
23
BK_RATIO
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV2_BK"
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
24
M_RATIO
Magnification ratio setting (%) of the M OPC drum traveling 
distance of "REV2_CL"
1-999 
(Entry of 20 corresponds 
to 100,000mm.)
15
25
REV1_RATIO
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV1"
1-999 20
26
REV1_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum 
traveling distance of  "REV1_SH”
1-255
20
27
BK_RATIO_SH
Magnification ratio setting (%) of the specified value of the 
BK OPC drum traveling distance of "REV2_BK_SH"
1-999 15
28
M_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum 
traveling distance of  "REV2_CL_SH”
1-999 15
29
COLOR BORDER
Magnification ratio setting (%) of the 
M position OPC drum traveling dis-
tance when executing the BK process 
control
BK process control 
is executed without 
judgment of ratio of 
the M OPC drum 
traveling distance. 
(Addition)
0 - 999
20
1 - 999(%)
30
BK ONLY
Disable/Enable setting and setting of 
the number of repetition of the BK 
process control when monochrome 
print is continued.
Enable 5 time
0 - 6
0
4
Disable 1-5 times
1 - 5
Inhibit
6
31
HT_DIF
Bias change difference value used for judgment of HT pro-
cess control
1 - 255
40
32
Registration 
adjustment set-
ting
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON pro-
cess control
0 - 2
0
0
ALL
1
CL/BK
2
33
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
34
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
0
35
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(MINUTE)
6
36
RG_BW_SYNC
Setting of Enable/Disable of the registration adjustment after 
a monochrome job
0-1
1
Mode
Item/Display
Content
Setting range
Default 
value
Page of 127
Display

Click on the first or last page to see other MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) service manuals if exist.