Read Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual online
MX-C250 SIMULATION 6 – 41
10
Process control
conditions set-
ting
conditions set-
ting
DAY
When the next warm-up if there is no
color job after a color job after pass-
ing the specified days from execution
of the previous color process control
color job after a color job after pass-
ing the specified days from execution
of the previous color process control
Disable of the speci-
fied days judgment
fied days judgment
0 - 999
0
1
1 - 999 days passing
999
11
HI-COV
Setting of the execution judgment of the process control in
continuous printing of high print ratio images
continuous printing of high print ratio images
0 - 2
0
12
LO-COV
Setting of the execution judgment of the process control in
continuous printing of low print ratio images
continuous printing of low print ratio images
0 - 1
0
13
REV1_SH
When the accumulated traveling distance of K or M OPC
drum unit reaches the specified level after turning ON the
power.
drum unit reaches the specified level after turning ON the
power.
0 - 1
1
14
REV2_BK_SH
When the accumulated traveling distance of K OPC drum
unit reaches the specified level from execution of the previ-
ous density correction.
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
15
REV2_CL_SH
When the accumulated traveling distance of M OPC drum
unit reaches the specified level from execution of the previ-
ous density correction.
unit reaches the specified level from execution of the previ-
ous density correction.
0 - 1
1
16
AVERAGE-PAGE
Setting of the number of pages of item HI-COV set value 2
1 - 10
3
17
LIMIT PAGE
Setting of the number of connected jobs of the process con-
trol and of the limit number of the process control
trol and of the limit number of the process control
1 - 10
10
18
PIX_RATIO_BK
Variable magnification ratio setting (%) of the BK toner count
specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
1 - 999
10
19
PIX_RATIO_CL
Variable magnification ratio setting (%) of the color (CMY)
toner count specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
toner count specified value
The set value of 100 corresponds to K print of A4 at the print
ratio of 5%.
1 - 999
10
20
INTERVAL TIME
Setting of the leaving time when turning ON the power
(including the sleep recovery time) (h: hour)
(including the sleep recovery time) (h: hour)
1 - 255
3
21
HUM HOUR
Interval setting of the temperature and humidity monitoring
time of "HUM" (unit: 10 minutes)
time of "HUM" (unit: 10 minutes)
1 - 24
2
22
HUM_DIF
The specified value of the area difference in humidity
between the level at execution of the previous control and the
current humidity (Applied to item HUM)
between the level at execution of the previous control and the
current humidity (Applied to item HUM)
1 - 9
2
23
BK_RATIO
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV2_BK"
BK OPC drum traveling distance of "REV2_BK"
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
24
M_RATIO
Magnification ratio setting (%) of the M OPC drum traveling
distance of "REV2_CL"
distance of "REV2_CL"
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
25
REV1_RATIO
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV1"
BK OPC drum traveling distance of "REV1"
1-999 20
26
REV1_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum
traveling distance of "REV1_SH”
traveling distance of "REV1_SH”
1-255
20
27
BK_RATIO_SH
Magnification ratio setting (%) of the specified value of the
BK OPC drum traveling distance of "REV2_BK_SH"
BK OPC drum traveling distance of "REV2_BK_SH"
1-999 15
28
M_RATIO_SH
Magnification ratio setting (%) of the M position OPC drum
traveling distance of "REV2_CL_SH”
traveling distance of "REV2_CL_SH”
1-999 15
29
COLOR BORDER
Magnification ratio setting (%) of the
M position OPC drum traveling dis-
tance when executing the BK process
control
M position OPC drum traveling dis-
tance when executing the BK process
control
BK process control
is executed without
judgment of ratio of
the M OPC drum
traveling distance.
(Addition)
is executed without
judgment of ratio of
the M OPC drum
traveling distance.
(Addition)
0 - 999
20
1 - 999(%)
30
BK ONLY
Disable/Enable setting and setting of
the number of repetition of the BK
process control when monochrome
print is continued.
the number of repetition of the BK
process control when monochrome
print is continued.
Enable 5 time
0 - 6
0
4
Disable 1-5 times
1 - 5
Inhibit
6
31
HT_DIF
Bias change difference value used for judgment of HT pro-
cess control
cess control
1 - 255
40
32
Registration
adjustment set-
ting
adjustment set-
ting
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON pro-
cess control
cess control
0 - 2
0
0
ALL
1
CL/BK
2
33
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
34
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
0
35
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(MINUTE)
6
36
RG_BW_SYNC
Setting of Enable/Disable of the registration adjustment after
a monochrome job
a monochrome job
0-1
1
Mode
Item/Display
Content
Setting range
Default
value