MX-C250  SIMULATION  6 – 40
44-28
Purpose
:
Adjustment/Setup
Function (Purpose)
Used to set the process control execution
conditions.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE: Set the items to the default values unless a change is spe-
cially required.
Mode
Item/Display
Content
Setting range
Default 
value
1
Process control 
Enable/Disable 
setting
INITIAL
YES
When warm-up after clearing the 
counter of the OPC drum and the 
developer unit
Enable
0 - 1
0
0
NO
Disable
1
2
SW  ON
When supplying the power (when 
clearing shut-off.)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control 
Enable
2
Pixel count judg-
ment (Judgement is 
based on the setting 
value of item K, L.)
3
3
TIME
After passing the specified time from 
leaving READY continuously (Time 
can be changed by INTERVAL TIME)
Color process con-
trol Enable
0 - 3
0
3
Process control Dis-
able
1
BK process control 
Enable
2
Pixel count judg-
ment
(Judgement is 
based on the setting 
value of item K, L.)
3
4
HUM_LIMIT
HUM judgment is made when turning 
ON the power and after passing 
TIME.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control 
Enable
2
5
Process control 
Enable/Disable 
setting
HUM
The temperature and humidity in side 
the machine are monitored only dur-
ing a job for every 2hours (set by item 
N). When the changes in the temper-
ature and the humidity are greater 
than the specified level (the set value 
of item O) in comparison with the pre-
vious process control.
Color process con-
trol Enable
0 - 2
0
0
Process control Dis-
able
1
BK process control 
Enable
2
6
REV1
YES
The accumulated traveling distance 
of BK or M position OPC unit  
reaches the specified level after turn-
ing the power.
Enable
0 - 1
0
0
NO
Inhibit
1
7
REV2_BK
YES
The accumulated traveling distance 
of BK position OPC drum unit 
reaches the specified level from exe-
cution of the previous density correc-
tion.
Enable
0 - 1
0
0
NO
Inhibit
1
8
REV2_CL
YES
The accumulated traveling distance 
of M position OPC drum unit reaches 
the specified level from execution of 
the previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
9
REFRESH 
MODE(*1)
YES
Select of YES/NO of the manual pro-
cess control key with key operation
Key operation dis-
play
0 - 1
0
1
NO
Key operation NO 
display
1
Page of 127