EEPROM Handling Procedure
 
 
 
WARNING
 
Never execute Sim16 to clear U2 trouble WITHOUT investigating the root cause of U2 trouble by 
using the following procedure:- 
 
1.  Ensure  to  follow  ESD  procedures  (using  an  earth  strap)  while  handling  the  PWBs  as  EEPROM 
data may become corrupted due to static charge.  
 
2.  Never insert the EEPROM to the socket in reverse.  
 
3.  U2 trouble occurs 100% if the machine is turned on after inserting the EEPROM in reverse. 
Execution of Sim16 to clear this U2 trouble will lead to corrupted data which cannot be 
fully recovered in the field.  
 
4.  Make  sure  that  PCU, MFP  &  SCAN  EEPROMs  are  not  switched  -  label  each  EEPROM 
for identification purposes before removing from the PWB.  
 
5.  Please handle EEPROMs with care to prevent bending or damage of pins.  
They will be broken if bent several of times. (This type of trouble has been reported many times.).  
 
6.  Do not use foamed styrol etc. for packing during the transportation of EEPROM.  
 
Foamed styrol easily generates static charge. In some cases, EEPROM is damaged just by placing 
it into foamed styrol.  
 
7.  Make sure to use black sponge (anti-static) for packing during transportation. The black sponge 
is also used to pack EEPROM provided as service parts.  
 
CAUTION: 
 
Please note that counter data and machine adjustment values are recorded in the EEPROM. If the data in 
EEPROM is corrupted, it is impossible to recover. In such cases, the only solution will be to initialise the
 
 
EEPROM therefore, counter data and adjustment values will be reset to “0” or “default”. Once all the 
adjustment values are set to default, it will be necessary to readjust all the adjustment values (ie. perform 
a complete run-up procedure). 
 
Caution to prevent damage on EEPROM: 
 
In case any trouble other than U2 occurs to the machine and the PWB has been replaced (eg. remove 
and reinstall the EEPROM onto the replacement PWB for example) and U2 trouble occurs right after 
power on, never execute Sim16 under this condition. 
 
As previously mentioned, the data in EEPROM will be corrupted after Sim 16 execution therefore:- 
 
 
In  such  cases,  EEPROM  may  have  been  inserted  in  reverse  or  MFP  and  PCU  EEPROM  may 
have been switched. 
 
Turn off the machine without execution of Sim16, install the correct EEPROM into the proper 
position (on the PWB), power on the machine again and then execute Sim16. This way, U2 
trouble should be cleared. 
 
Sim16 should only be executed to clear U2 trouble if it occurred without performing any repair 
or maintenance as such. 
 
As previously mentioned, execution of Sim16 won’t clear artificially-generated U2 errors. Instead, it may 
actually damage the EEPROM, HDD storage and backup data. 
 
 
 
 
 
 