Read Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man2) Handy Guide online
Electrical
High Voltage Settings
The adjustment value of each colour mode is specified on the information label attached to
the High Voltage Power PWB.
the High Voltage Power PWB.
Using Simulation 8-01 (DV Bias Setting) & Sim 8-02 (MC Grid Bias Setting), enter the
values specified, especially after U2 trouble:-
values specified, especially after U2 trouble:-
DV BIAS VOLTAGE – SIMULATION 08-01
Item
Mode
Item/Display
Adjustment
Range
M_DVB_K
Middle Speed
DV Bias Voltage
M_DVB_C
M_DVB_M
M_DVB_Y
0-600
L_DVB_K
Low Speed
DV Bias Voltage
L_DVB_C
L_DVB_M
L_DVB_Y
MAIN CHARGE GRID VOLTAGE – SIMULATION 08-02
Item
Mode
Item/Display
Adjustment
Range
M_GB_K
Middle Speed
MC Grid Voltage
M_GB_C
M_GB_M
M_GB_Y
150-850
L_GB_K
Low Speed
MC Grid Voltage
L_GB_C
L_GB_M
L_GB_Y
Note:
The adjustment value may differ depending on the high voltage power PWB.
The adjustment value may differ depending on the high voltage power PWB.
As the adjustment value label is attached on the high voltage PWB, the Main PWB must
be removed in order to check the adjustment value.
be removed in order to check the adjustment value.