Firmware Upgrade
 
 
 
USB Memory Device: 
 
1.  Using a PC, copy the MX-C250/300 series firmware (*.sfu) onto the root directory of a USB 
memory device (as indicated below):-  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2.  Power ON the MX-C250/300 series machine.  
 
3.  Insert the USB memory device containing the firmware file into the front USB Port.  
 
4.  Enter Simulation 49-01.  
 
Note:  If  no  USB  memory  device  is  detected  or  the  firmware  file  is  not  located  on  the 
root directory, No File Detected will be displayed (as shown below):-  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.  Using  the  UP  &  DOWN  navigation  keys  on  the  operation  panel,  select  the  required 
firmware file (*.sfu):-  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
6.  The current and the updated firmware version will be shown within the display  – press the 
OK button or Copy START key to execute.  
 
 