MX-B382 (serv.man6). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 122

Read Sharp MX-B382 (serv.man6) Service Manual online

MX-B382/B402  SIMULATION  5 – 54
 
50-2
Purpose
Adjustment
Function (Purpose) Used to adjust the copy image position and
the image loss. (This simulation is a simpli-
fied version of SIM 50-1).
Section
Operation/Procedure
The magnification ratio adjustment in the sub scanning direction
must be executed in advance. (SIM48-01)
1)
Set item A (L1) and item B (L2) to 0.
2)
Place a rule on the left edge of the document table, and make
a copy at a magnification ratio of 200%.
3)
Measure the length of L1 and L2 on the copied image in the
unit of 0.1mm (referring to the figure below). Enter the adjust-
ment values of L1 x 10 and L2 x 10. Be sure to enter the both
adjustment values of L1 and L2.
L1: Distance from the lead edge of the copied image to 10mm
scale.
L2: Distance from the paper lead edge to the copy image lead
edge.
4)
Press [EXECUTE] key. (The set value is saved.)
5)
Make a copy at the magnification ratio of 100%, and adjust the
lead edge void.
Same as the adjusted items of SIM50-01 except for A and B.
The values adjusted with A and B are reflected to the document
lead edge reference position (RRC-A) of SIM50-01 and all the
paper lead edge positions (RRCB-**).
All adjustment items: 1 step = 0.1mm change
 
50-5
Purpose
Adjustment
Function (Purpose) Used to adjust the print lead edge image
position. (PRINTER MODE)
Section
Operation/Procedure
1)
Select a target adjustment item (DEN-C) with [
] [] key.
2)
Enter the adjustment value using the 10-key.
3)
Press [EXECUTE] key.
The set value is saved, and the adjustment check pattern is
printed.
4)
Measure the distance from the paper lead edge the adjustment
pattern to the image lead edge, and check to confirm that it is
in the standard adjustment value range.
Standard reference value: 3.0
2.0mm
When the adjustment value is increased, the distance from the
paper lead edge to the image lead edge is increased. When the
adjustment value is decreased, the distanced is decreased.
When the set value is changed by 1, the distance is changed by
about 0.1mm.
Item/Display
Description
Setting 
range
Default 
value
A
Actual 
measurem
ent value
L1
Distance from the 
image lead edge to 
the scale of 10mm. 
(Platen 400%, 
0.1mm increment)
0 - 999
-
B
L2
Distance from the 
paper lead edge to 
the image lead edge 
(0.1mm increment)
0 - 999
0
C
Image loss 
area 
setting 
value
LEAD
Lead edge image 
loss amount setting 
(When the 
adjustment value is 
increased, the image 
loss is increased.)
0 - 99
30
D
SIDE
Side edge image 
loss amount setting 
(When the 
adjustment value is 
increased, the image 
loss is increased.)
0 - 99
20
Paper lead
edge
L1
L2
200% enlargement copy
Fig. 1
E
Void area 
adjustment
DENA
Lead edge void area 
adjustment (When 
the adjustment value 
is increased, the void 
is increased.)
1 - 99
30
F
DENB
Rear edge void area 
adjustment (When 
the adjustment value 
is increased, the void 
is increased.)
1 - 99
30
G
FRONT/
REAR
FRONT/REAR void 
amount adjustment 
(When the 
adjustment value is 
increased, the void is 
increased.)
1 - 99
30
Item/Display
Description
Setting 
range
Default 
value
Page of 127