MX-B201D (serv.man8). MX-FX12 Service Manual - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp MX-B201D (serv.man8) Service Manual online

MX-FX12  FAX SOFT SWITCH  2 - 3
S
W
4
5
Recall interval in 
busy
Used to set the interval for the next call when busy tone is detected 
in communication.
3min
0
Refer to User program 
“RECALL INTERVAL 
(BUSY)”.
When a value outside the 
set range is set, the initial 
value is set.
6
Setting is made in binary input.
0
Binary input
7
Bit  No.
5
6
7
8
1
Set range
1 to 15min
8
4 to 15min (Taiwan)
1
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data 
accumulation wait 
time
Used to set wait time for accumulation of image data before 
sending image data directly.
6sec.
0
Bit No.
3
4
6sec.
0
0
4
5sec.
0
1
0
4sec.
1
0
3sec.
1
1
5
Pause time setup
Used to set pause time when registering dials.
2sec.
0 When a value outside the 
set range is set, the initial 
value is set.
6
Binary input
0
7
Bit  No.
Set range
5
6
7
8
1 to 15sec.
1
8
0
S
W
6
1
ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when 
SW34-1 (V.34 mode function) is ON and send is made other than 
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote 
machine may perform checking, when SW43-1 (V.34 mode 
function) is ON, this function is invalid in reception.
Yes
1
1: Yes
0: No
2
CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
Dial tone ON/OFF 
detection time 
lower limit (Option)
Used to set the minimum required time for detection of dial tone.
This is a setting to enhance SW7-1.
It follows SW7-1. 0
1: SW7-1 x 0.7
0: It follows SW7-1.
6
EOL detection 
timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
13sec.
0
1: 25sec.
0: 13sec.
7
Countermeasure 
for echo in 
reception (CED 
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
500ms
1
1: 500ms
0: 75ms
8
Countermeasure 
for echo in 
transmission (After 
reception of DIS, 
hold time up to 
signal send is set.)
Used to set the interval from DIS receive to DSC signal send.
500ms
0
1: 800ms
0: 500ms
S
W
7
1
Dial tone ON/OFF 
detection time 
lower limit 
(Intermittent 
detection)
Used to set the minimum required time for detection of dial tone 
when the dial tone detection is set to “YES” and the kind of the dial 
tone detection is set to “Continuous.”
100ms
0
1: 300ms
0: 100ms
2
Dial tone detection Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a 
certain time (3.5sec.).
Yes
1
1: Yes
0: No
3
Busy tone 
detection
Used to set YES/NO of busy tone detection when calling out.
Yes
1
1: Yes
0: No
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56
Display