Read Sharp MX-B201D (serv.man8) Service Manual online
MX-FX12 FAX SOFT SWITCH 2 - 3
S
W
4
5
Recall interval in
busy
busy
Used to set the interval for the next call when busy tone is detected
in communication.
in communication.
3min
0
Refer to User program
“RECALL INTERVAL
(BUSY)”.
When a value outside the
set range is set, the initial
value is set.
“RECALL INTERVAL
(BUSY)”.
When a value outside the
set range is set, the initial
value is set.
6
Setting is made in binary input.
0
Binary input
7
Bit No.
5
6
7
8
1
Set range
1 to 15min
8
4 to 15min (Taiwan)
1
S
W
5
1
Inhibited to use
0
2
0
3
G3 send data
accumulation wait
time
accumulation wait
time
Used to set wait time for accumulation of image data before
sending image data directly.
sending image data directly.
6sec.
0
Bit No.
3
4
6sec.
0
0
4
5sec.
0
1
0
4sec.
1
0
3sec.
1
1
5
Pause time setup
Used to set pause time when registering dials.
2sec.
0 When a value outside the
set range is set, the initial
value is set.
value is set.
6
Binary input
0
7
Bit No.
Set range
Set range
5
6
7
8
1 to 15sec.
1
8
0
S
W
6
1
ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode
function) is ON, this function is invalid in reception.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of “NO” is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode
function) is ON, this function is invalid in reception.
Yes
1
1: Yes
0: No
2
CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Yes
1
1: Yes
0: No
3
Inhibited to use
0
4
0
5
Dial tone ON/OFF
detection time
lower limit (Option)
detection time
lower limit (Option)
Used to set the minimum required time for detection of dial tone.
This is a setting to enhance SW7-1.
This is a setting to enhance SW7-1.
It follows SW7-1. 0
1: SW7-1 x 0.7
0: It follows SW7-1.
6
EOL detection
timer
timer
Used to set detection timer of EOL (EndOfLine) in Phase C receive.
13sec.
0
1: 25sec.
0: 13sec.
7
Countermeasure
for echo in
reception (CED
tone send interval)
for echo in
reception (CED
tone send interval)
Used to set the interval from CED send to FSK signal send of DIS.
500ms
1
1: 500ms
0: 75ms
8
Countermeasure
for echo in
transmission (After
reception of DIS,
hold time up to
signal send is set.)
for echo in
transmission (After
reception of DIS,
hold time up to
signal send is set.)
Used to set the interval from DIS receive to DSC signal send.
500ms
0
1: 800ms
0: 500ms
S
W
7
1
Dial tone ON/OFF
detection time
lower limit
(Intermittent
detection)
detection time
lower limit
(Intermittent
detection)
Used to set the minimum required time for detection of dial tone
when the dial tone detection is set to “YES” and the kind of the dial
tone detection is set to “Continuous.”
when the dial tone detection is set to “YES” and the kind of the dial
tone detection is set to “Continuous.”
100ms
0
1: 300ms
0: 100ms
2
Dial tone detection Used to set whether dial tone is detected or not when calling out.
When set to 1, dial tone is detected before calling out.
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec.).
When set to 0, dial tone is not detected and dialing is made after a
certain time (3.5sec.).
Yes
1
1: Yes
0: No
3
Busy tone
detection
detection
Used to set YES/NO of busy tone detection when calling out.
Yes
1
1: Yes
0: No
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other MX-B201D (serv.man8) service manuals if exist.