MX-FX12  FAX SOFT SWITCH  2 - 4
S
W
7
4
Dial tone 
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF 
detection time 
upper limit 
(Intermittent 
detection)
Used to set the upper limit time for detection of dial tone when the 
dial tone detection is set to “YES” and the kind of the dial tone 
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not 
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of 
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination 
display time when 
one-touch key is 
pressed
Used to set the time from displaying the destination to the next 
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the 
set range is set, the initial 
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory 
transmission/
direct transmission 
default setup
Used to set whether memory send is ON or direct send is made 
(OFF) in the memory mode when pressing [Clear All] key or auto 
clear.
Memory 
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF 
detection time 
upper limit 
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms 
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online 
send.
Yes
1
1: Yes
0: No
5
Remote select 
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program 
“REMOTE RECEPTION 
SELECT”.
1: Yes
0: No
6
Number of 
checking CNG
Used to set the number of times of CNG detection for judgment of 
detection.
3 times
0
When a value outside the 
set range is set, the initial 
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 56