Read Sharp MX-B201D (serv.man8) Service Manual online
MX-FX12 FAX SOFT SWITCH 2 - 4
S
W
7
4
Dial tone
monitoring time
monitoring time
Used to set the monitoring time when detecting dial tone.
5sec.
0
1: 10sec.
0: 5sec.
5
Dial tone ON/OFF
detection time
upper limit
(Intermittent
detection)
detection time
upper limit
(Intermittent
detection)
Used to set the upper limit time for detection of dial tone when the
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
dial tone detection is set to “YES” and the kind of the dial tone
detection is set to “Intermittent.”
If a dial tone is detected for more than this upper limit time, it is not
considered as a dial tone.
700ms
0
1: 400ms
0: 700ms
6
Max. length of
reception
reception
Used to set max. length of reception for long document.
1.5m
0
1: No limit
0: 1.5m
7
Destination
display time when
one-touch key is
pressed
display time when
one-touch key is
pressed
Used to set the time from displaying the destination to the next
operation in one-touch dial or reduction dial.
operation in one-touch dial or reduction dial.
2sec.
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
Bit No.
7
8
8
2sec.
0
0
0
4sec.
0
1
6sec.
1
0
S
W
8
1
Memory
transmission/
direct transmission
default setup
transmission/
direct transmission
default setup
Used to set whether memory send is ON or direct send is made
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
(OFF) in the memory mode when pressing [Clear All] key or auto
clear.
Memory
transmission
0
1: Direct transmission
0: Memory transmission
2
Inhibited to use
0
3
Dial tone ON/OFF
detection time
upper limit
(Option)
detection time
upper limit
(Option)
Used to set the upper limit time for detection of dial tone.
This is a setting to enhance SW7-5.
This is a setting to enhance SW7-5.
Follows SW7-5.
0
1: SW7-5=0:1000ms
SW7-5=1:1200ms
0: Follows SW7-5.
4
Quick online send Used to set whether quick online send function is enabled or not.
When set to 0, send in memory mode ON is made in memory send.
When set to 1, send in memory mode ON is made in quick online
send.
When set to 1, send in memory mode ON is made in quick online
send.
Yes
1
1: Yes
0: No
5
Remote select
function
function
Used to set whether remote reception function is enabled or not.
Yes
1
Refer to User program
“REMOTE RECEPTION
SELECT”.
“REMOTE RECEPTION
SELECT”.
1: Yes
0: No
6
Number of
checking CNG
checking CNG
Used to set the number of times of CNG detection for judgment of
detection.
detection.
3 times
0
When a value outside the
set range is set, the initial
value is set.
set range is set, the initial
value is set.
7
Binary input
1
Bit No.
6
7
8
8
Set range
1 to 4 times
1
S
W
9
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
10
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark
Click on the first or last page to see other MX-B201D (serv.man8) service manuals if exist.