MX-6240N, MX-7040N (serv.man30). Section 11 Various Storage Data Handling - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 18

Read Sharp MX-6240N / MX-7040N (serv.man30) Service Manual online

MX-7040N  VARIOUS STORAGE DATA HANDLING  11 – 18
Phenomenon 3
Though the target HDD is connected, it is not displayed.
Cause
The target HDD is not registered in the Setup.ini file. 
Cable or other device trouble, HDD trouble
Countermeasures
1. Reboot RIB Buster, and click the frame section.
2. If the trouble is not solved by procedure 1. , replace 
the Setup. ini file and the RIB Buster {YYYYMMDD} 
with the latest version, and execute procedure 1. .
3. If the trouble is not solved by procedure 2. , 
disconnect and connect the cable, change the 
devices, and reboot the RIB Buster. Then execute 
procedure 1. .