Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-1110 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1. Model Name:  MX-FR36U (Options for MX-6240N/7040N) 
 
2. Description:  Upgrade of ICUM, ICU1, and ICU2-ROM 
 
From January 2013 production 
ROM control No. 
ICUM 
ICU1 
ICU2 
B00 
0210Sc00 
0210Sc00 
0101Sc00 
 * ICU above is the version described in the ROM management label.  Check that the actual  
  version is: ICUM(MAIN): 02.10.Sc.00/ICUM(SUB): 02.10.S1.00/LANGUAGE:  
  01.04.S1.00/ UICONTENTS: 02.10.Sc.00/PCL(PROFILE):01.00.S1.00; by Sim22-5. 
 * ICU1 above is also the version described in the ROM management label.  Check that the  
  actual version is: ICU1(MAIN): 02.10.Sc.00/ICU1(BOOT): 01.01.Sc.00/ICU1(SUB):  
  01.00.S1.0c; by SIM22-5.  
  Item of change: See the attached sheets.  
 Note) This report is a T/R for the data security kit option, corresponding to general 
       T/R No. CCE-1104 
 
 
MX-FR36U - ROM UPGRADE ..... (1). 
Ver. 02.10.Sc.00
 
TECHNICAL BULLETIN 
 
Date:  
2
nd
 April 2013 
Model:  
MX6240N – MX7040N 
Ref.:   
CCE-1110 
Colour:  
White 
Page:  
1 of 3 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-1110 
 
[Description] 
No. 
Item 
Details 
1  Printer 
When printing from Adobe Indesign in Mac OS environment, in some cases, PS error 
occurred.  This problem has been corrected. 
2  Printer 
When executing the consecutive print jobs in the environment where the external 
accounting software was used, in some cases, the error occurred.  This issue has been 
corrected. 
3  Printer 
When executing the print job with the invalid user, the user name/log-in name in the job 
log became User Unknown/"PC log-in name specified by the driver".  This has been 
modified to become "User name specified by the driver"/"Log-in name specified by the 
driver (User number). 
4  Printer 
When printing the data with special font header, the PCL XL error occurred.   
This problem has been corrected. 
5  Printer 
When printing PCL5 data with the mixed originals of Portrait/Landscape that contains 
RESET COMMAND in the middle of the job, the print direction would become 
inappropriate in the process of printing.  This problem has been corrected. 
6  Printer 
When printing PCL5 data with the certain font, the machine locked up.  This problem 
has been corrected. 
7  Printer 
Even after performing the colour adjustment from Printer Settings on Web Page, the 
setting could not be reflected when printing with PS.  This problem has been corrected. 
Network 
communication 
On SMB server (NAS) feature, if a print job was sent while several clients were 
connecting to (browsing) NAS folder, MFP showed Waiting and never started printing.  
This problem has been corrected.  
Network 
communication 
After security patch KB2585542 was applied to Windows, the connection using IPP SSL 
would fail.  This problem has been corrected.  
10 
Network 
communication 
When "DNS Update" is "Enable", the machine hangs up due to the connection with the 
external authentication application.  This problem has been corrected. 
11  Web Page 
If SSL authentication was enabled on the connection test of "Internet Fax Setting" and 
"E-mail Print Settings" on Web Page, the connection test passed as long as the 
communication with SSL was "Successful" even though the username/password were 
wrong.   
12  Authentication 
When Caps Lock is ON on the hardware keyboard, in some cases, the authentication 
error occurred when authenticating with the card.  This problem has been corrected. 
13  Authentication 
Modification has been made to be able to select by Soft SW whether to authenticate the 
user already logged in by being authenticated with Active Directory or not when 
receiving the print data. 
Sim55-3 SW No.30 Data5 
0: Authenticate 
1: Not authenticate (Default) 
14  Authentication 
Modification has been made to prevent the invalid user from the log-in when the 
authentication is required in Active Directory environment. 
15  Authentication 
Modification has been made to open not Folder Select screen but Main Folder screen 
first when moving to Document Filling mode during the external authentication.    
16  Authentication 
Modification has been made not to display "Card reader is not connected" message until 
the initialization is finalized by monitoring the initialization of IC card reader when starting 
up/recovering from Energy Save. 
17  OSA 
Machine occasionally locked up with "Please wait" message being displayed after 
performing a Copy job using OSA application.  This problem has been corrected. 
18  OSA 
When reading the card containing the keyboard information like Shift etc using OSA 
application, the shift data would be displayed on the operation panel as the garbage 
information.  This problem has been corrected. 
19  OSA 
When using in Equitrac environment, the log-in name information remained in the 
password entry section when the screen changed to the password entry screen after 
entering the log-in name.  This problem has been corrected. 
20  OSA 
When using Equitrac environment, the Auto Logout occasionally did not function even 
when leaving the machine after logging in to the application.  This problem has been 
corrected. 
 
 
 
Sharp Electronics (UK) Ltd., Technical Services Group
 
CCE-1110 
 
No. 
Item 
Details 
21  Copier 
When performing the program registration data which was set to 2-sided print, if the 
paper type which was selected as "Disable Duplex" was set up to the tray, in some 
cases, the checkmark for 2-sided print setting of the program registration would be OFF 
during the process of copying, and then the data would be printed not on the double-
sided but on the single-side.  This problem has been corrected.   
22  Copier 
Modification has been made to store also the paper size for the bypass tray on Copy Job 
Program. 
23  Copier 
Modification has been made to display the error message in addition to the error sound 
in the case of the condition that Dual Page Copy function cannot be carried out. 
24  Scanner 
Scan to FTP now supports "PASV mode". 
25  PC-FAX 
26  UI 
When there were a lot of custom folders, displaying the user list screen became slow.  
This problem has been corrected. 
27  UI 
Message which indicates toner end has been changed to “Prepare a new toner”. 
28  Simulation 
Modification has been made to establish "IMS CONTROL" in Auditor setting of SIM26-03 
so that it is selectable whether to enable or disable the limitation of Image Send mode 
when setting Auditor.  (Default: OFF) 
29  E-mail alert 
Modification has been made to be able to select whether to send more than one Alert 
Mails for the same event by Soft switch when recovering from Energy Save.   
SIM55-03   SW No. 28  Data 3 
 0: Send more than one alert mails until the event is cleared. (Default) 
 1: Send the alert mail only once. 
30  Option 
When 1K saddle finisher was installed, MFP locked up when reaching to the maximum 
number of the saddle staple sets.  This problem has been corrected.  
31  Option 
When using the Web browsing extension KIT, the keyboard layout was set to Japanese-
keyboard.  This has been corrected. 
32  Others 
Modification has been made not to export the items (Address Book etc) which should be 
exported with storage backup when exporting the device cloning data from System 
Settings on the machine. 
33  Others 
When moving the device cloning data from the old model that "Default Preview" function 
does not exist, in some cases, the copy job would not be output.  This problem has been 
corrected.  
34  Others 
If the device cloning data of the machine with "Preview" being set was imported to the 
machine with no "Preview" function, the copy would be unable to be performed.  This 
problem has been corrected.  
35  Others 
Modification has been made to change the frequency to obtain the information of the 
remaining toner using MIB with SOFT SW.  
 
SIM55-3 SW No. 32  Data 2 
 0: every 25% (Default) 
 1: every 5% 
36  Others 
Modification has been made to be able to acquire the maintenance code and error code 
with MIB. 
37  Others 
Modification has been made not to display the message that the data is changed when 
the address is registered from Sharp Desk Mobile. 
38  Others 
Support for the change of ICU2/BIOS flash memory maker (Macronix/Eon are now both 
supported) and also the change of ICU1/ICU2 memory. 
39  Others 
Modification has been made to power OFF the machine after 1 minute at the completion 
of the operation if the machine is turned OFF with Power ON/OFF Schedule Setting 
while the user is operating some function like Preview etc. 
 
 
 
 
Page of 3
Display

Download Sharp MX-6240N / MX-7040N (serv.man153) Technical Bulletin

Here you can read online and download Sharp MX-6240N / MX-7040N (serv.man153) Technical Bulletin in PDF. MX-6240N / MX-7040N (serv.man153) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp MX-6240N / MX-7040N (serv.man153) Copying Equipment. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.