Read Sharp MX-6240N / MX-7040N (serv.man30) Service Manual online
MX-7040N VARIOUS STORAGE DATA HANDLING 11 – 17
5)
Select the target HDD to delete the mirroring information.
6)
Click [Clear RIB in HDD] button.
7)
Click [OK] button. (The mirroring information is deleted.)
8)
After completion of deleting the mirroring information, "OK" is
displayed.
displayed.
(3)
Kinds of errors, causes and remedies
Phenomenon 1
An error indicating an abnormality in the Setup.ini file when booting
the RIB Buster software.
the RIB Buster software.
Phenomenon 2
The mirroring information has not been deleted normally.
Cause
Setup.ini file does not exists, or there is any
abnormality in the file.
abnormality in the file.
Countermeasures
Check to confirm that there is Setup.ini file in the
proper directory and that there is no abnormality in
the descriptions.
proper directory and that there is no abnormality in
the descriptions.
Cause
Temporary communication trouble, cable or other
device trouble, HDD trouble
device trouble, HDD trouble
Countermeasures
1. Click [Clear RIB in HDD] button again.
2. If the trouble is not solved by procedure 1. ,
disconnect and connect the cable, change the
devices, and reboot the RIB Buster. Then execute
procedure 1. .
2. If the trouble is not solved by procedure 1. ,
disconnect and connect the cable, change the
devices, and reboot the RIB Buster. Then execute
procedure 1. .
Click on the first or last page to see other MX-6240N / MX-7040N (serv.man30) service manuals if exist.