MX-6201N, MX-7001N (serv.man27). DSPF SECTION - Sharp Copying Equipment Service Manual (repair manual). Page 21

Read Sharp MX-6201N / MX-7001N (serv.man27) Service Manual online

MX-7001N  DSPF SECTION  C – 21
3)
Loosen the screws (C), and lower the angle adjustment plate
(D). Open the DSPF unit (E).
4)
Remove the screw (F), and remove the left rear lower cabinet
(G).
5)
Remove the resin E-ring (H), and remove the PS knob (I).
6)
Remove the screws (J), and remove the PS outer PG (K).
7)
Remove the screws (L), and remove the PS front PG (M).
8)
Remove the screw (N), and disconnect the connector (O), and
remove the DSPF paper pass sensor 3 (P).
9)
Remove the screws (Q), and remove the lift-up PG (R).
10) Remove the screw (S), and remove the spring (T). Remove
the belt (U), and disengage the pawls (V), and remove the
platen roller (W).
E
C
C
D
F
G
H
I
J
J
K
L
L
M
P
N
O
e
Q
Q
R
U
S
T
V
V
W