Restoring functionality after service
Restoring functionality after service
To complete any service procedures performed on the Fiery X3e, install the Fiery X3e
inside the print engine as described in the Fiery X3e installation instructions (not
provided in this guide) and verify that it is working properly. To verify the installation,
check the connections of the Fiery X3e first to the print engine and then to the network.
inside the print engine as described in the Fiery X3e installation instructions (not
provided in this guide) and verify that it is working properly. To verify the installation,
check the connections of the Fiery X3e first to the print engine and then to the network.
T
O
REASSEMBLE
AND
VERIFY
THE
F
IERY
X3
E
1.
Reseat any cables, boards, or devices that you may have loosened or removed during
inspection or service (see Figure B on page 4 and “Checking connections” on page 9).
inspection or service (see Figure B on page 4 and “Checking connections” on page 9).
2.
Make sure the following components are installed and connected properly according to
their procedures:
their procedures:
• On the motherboard:
Scan card, battery, CPU cooling system, optional DIMM (if present).
• In the pan:
Motherboard, HDD, enclosed fan, top panel.
3.
If you removed the Fiery X3e from the print engine, reinstall it:
• Lift the Fiery X3e near the print engine and route the power cables from the
print engine through the pan cutout.
• Hook the Fiery X3e to the print engine and attach the Fiery X3e to the print engine
with the 3 screws you removed earlier.
• Tighten the bottom 3 screws that you loosened earlier.
4.
Make sure the following cables are installed and connected properly:
• Power cables to the power switch (2), HDD, and motherboard at ENG_PWR
• Enclosed fan cable to the motherboard at ENC_FAN
• HDD cable to the motherboard at PRIMARY IDE DRIVE
5.
Make sure both service switches are in normal position (away from the motherboard).
6.
Slide the lid on the Fiery X3e pan until it hooks into place and attach the lid to the pan
with the 8 screws you removed earlier.
with the 8 screws you removed earlier.
7.
Connect the external cables to the Fiery X3e.
• At the top panel: Interface cables (2) to the motherboard and the Scan card.
• At the faceplate: network cable and, if necessary, the parallel port cable.
8.
If you installed a new HDD, install system software according to the procedure in
“System software” on page 25.
“System software” on page 25.
A spare HDD is shipped without system software.