15
Removing and replacing Fiery X3e components
Battery
The battery on the Fiery X3e is located at BT100. To replace it, see “Specifications” on 
page 35.
CAUTION:  There is danger of explosion if the battery is replaced with the incorrect type. 
Replace only with the same type recommended by the manufacturer. Dispose of used 
batteries according to local regulations.
T
O
 
REPLACE
 
THE
 
MOTHERBOARD
 
BATTERY
1.
After removing the Fiery X3e from the print engine as described on page 8, pull the old 
battery out of its socket (see Figure K).
2.
Place the new battery under the top leads and over the bottom leads. Make sure the 
positive (+) side of the battery is facing up. 
F
IGURE
 K
Motherboard battery and socket
3.
Reassemble the Fiery X3e and verify its functionality as described on page 20.
N
OTE
:
When you power on the Fiery X3e, let the Fiery X3e reach Idle, then power off 
and on again to reinitialize the realtime clock. 
4.
Configure the time and date in Setup.
N
OTE
:
If the time and date do not remain configured, check the battery installation. To 
make proper electrical contact, the battery must be in contact with the top leads on the 
top and the bottom leads on the bottom (see Figure K). 
Top leads (2)
Bottom leads (2)
Socket
+
Battery
Slide the battery under the 
top leads
Lay the battery on the 
bottom leads
Page of 54
Display