Read Sharp AR-PE3 (serv.man6) User Guide / Operation Manual online
15
Removing and replacing Fiery X3e components
Battery
The battery on the Fiery X3e is located at BT100. To replace it, see “Specifications” on
page 35.
page 35.
CAUTION: There is danger of explosion if the battery is replaced with the incorrect type.
Replace only with the same type recommended by the manufacturer. Dispose of used
batteries according to local regulations.
Replace only with the same type recommended by the manufacturer. Dispose of used
batteries according to local regulations.
T
O
REPLACE
THE
MOTHERBOARD
BATTERY
1.
After removing the Fiery X3e from the print engine as described on page 8, pull the old
battery out of its socket (see Figure K).
battery out of its socket (see Figure K).
2.
Place the new battery under the top leads and over the bottom leads. Make sure the
positive (+) side of the battery is facing up.
positive (+) side of the battery is facing up.
F
IGURE
K
Motherboard battery and socket
3.
Reassemble the Fiery X3e and verify its functionality as described on page 20.
N
OTE
:
When you power on the Fiery X3e, let the Fiery X3e reach Idle, then power off
and on again to reinitialize the realtime clock.
4.
Configure the time and date in Setup.
N
OTE
:
If the time and date do not remain configured, check the battery installation. To
make proper electrical contact, the battery must be in contact with the top leads on the
top and the bottom leads on the bottom (see Figure K).
top and the bottom leads on the bottom (see Figure K).
Top leads (2)
Bottom leads (2)
Socket
+
Battery
Slide the battery under the
top leads
top leads
Lay the battery on the
bottom leads
bottom leads
Click on the first or last page to see other AR-PE3 (serv.man6) service manuals if exist.