18
Removing and replacing Fiery X3e components
F
IGURE
 L
HDD in the Fiery X3e
T
O
 
REMOVE
 
THE
 HDD
C
AUTION
:
Wear an ESD grounding wrist strap and follow standard ESD (electrostatic 
discharge) precautions while handling Fiery X3e components.
1.
Remove the Fiery X3e from the print engine, as described on page 8.
Disconnect the power cable from the HDD. 
2.
Remove the four screws that secure the HDD to the pan (see Figure L). 
Set the screws aside.
3.
Remove the HDD cable from the HDD.
4.
Place the HDD in an antistatic bag.
Do not touch the drive with magnetic objects, such as magnetic screwdrivers. Do not 
place items near the hard disk drive that are sensitive to magnets, such as credit cards and 
employee ID cards. See “Proper handling” on page 17. 
Pan
HDD cable 
(can remain attached 
to the motherboard) 
HDD 
N
OTE
For clarity, the 
motherboard is not 
shown.